Sanyo VCC-4594P Instruction Manual page 11

Color ccd camera
Hide thumbs Also See for VCC-4594P:
Table of Contents

Advertisement

CONNECTIONS
(Video signal connections)
: VIDEO IN
: VIDEO OUT
(VCC-4592P only)
Basic connection for monitoring or recording
The peripheral devices (VCR, monitor, lens, etc.) and cables are
sold separately.
1
Make the video signal connection between the camera and
the monitor or time lapse VCR.
2
Use a commercially available 12 V DC adaptor.
Connect an DC 12 V power source to the 12 V DC input terminal
on the back of the camera.
2A:
When using this unit, the supplied clamping core (A or B) must be
installed on the power cord and BNC cable, in order to prevent
electromagnetic interference to the other devices connected.
(A)
1
2A
(A)
+
NC
2
2A
(B)
3
The POWER indicator (A) will light. Adjust the picture on the
monitor using the Brightness and Contrast controls.
Coaxial cable type and maximum length
Cable type RG-59U (3C-2V), 250 m maximum.
Cable type RG-6U (5C-2V), 500 m maximum.
Cable type RG-11U (7C-2V), 600 m maximum.
CAUTION:
The RG-59U type cable should not be run through electrical
conduits or through the air.
Using CCTV/Video-grade coaxial cable.
2A
(A)
2A
(B)
DC 12 V
+