TX Power Out Test

TX Frequency
MHz
834.9900
dB
TX Pow er
27.60
Inp ut Po rt
Tun e Mo de
Auto /M an u al
RF in/A n t
Tun e Freq
IF Filter
834 .99 000 0
230 kH z
TX Pwr Zero
Ex t T X K ey
Zero
On/Off
Test Mode Commands:
Using RadioComm software (Please refer to the
RadioComm Test Procedure)
- Suspend Radio
- Load synthesizer to channel 333
- Set power level to step X,
where X is a power level from 1 to 7
- Turn on Carrier
The TX Power Out specification for each
portable power level is as follows:
Power Step 225dBm - 29dBm
Power Step 321.5dBm - 25.5dBm
Power Step 417.5dBm - 21.5dBm
Power Step 513.5dBm - 17.5dBm
Power Step 69.5dBm - 13.5dBm
Power Step 75.3dBm - 9.5dBm
Note: When taking measurements, remem-
ber to compensate for cable loss.
TX TEST
FM Dev iation
11.58
A F Freq
1.00000
AF A nl In
To Screen
A FG en1 Freq
1 .00 00
FM Demo d
KHz
CA LL CN TL
SMS
Filter 1
AFGen1 Lvl
AU THEN
6.00
50 Hz H PF
Filter 2
V
15 kHz L PF
RX TEST
D e-E mp hasis
75 0 . s /Off
Config
D etector
TESTS
Pk + - M ax
Communications Analyzer
KHz
Setup
• Select TX button from the Screen
Control panel
KHz
• PWR ismeasured in dBm
• Set Frequency Measurement to
auto or manual (display will show
CDM A
TX Freq. Error)
• SetTX frequency to 834.990 MHz
• SetIF filter to 230 kHz
A nalog
• SetAF Filter 1 to 50 Hz
• SetAF Filter 2 to 15 kHz
• SetAF gen1 for 1 kHz frequency
at 6V level (output will go to the au-
dio port)
37
Motorola Confidential Proprietary
Test Procedures
: