9).Remove the two screws (C.C.SCREW,3X6,F/ZN-3C) that secure the CF Plate, and
remove the CF Plate together with the USB Board Assy. and CF Slot Assy.
(to
Removing the USB Board Assy./CF Slot Assy. (EMP-1825/1815 only) (p.
10).Remove the screw (C.C.SCREW,3X6,F/ZN-3C) that secures the IM Fastening Plate,
and remove the IM Fastening Plate.
11).Remove the IM Shield Plate from the IM Board Assy.
12).Remove the USB Cable from the connector (CN801) on the IM Board Assy.
13).Remove the CF Slot Shading Sheet from the IM Board Assy.
14).Remove the Connector Shading Sheet from the IM Shied Plate.
15).Remove the following parts from the IM Board Assy.
• Gasket 5x5 x 3 (1)
• Gasket 10x10 x 2 (2)
• LAN Shading Sheet
• USB Shading Sheet;B
• EMI Suppressor* x 2 (EMP-1815's case)
EMI Suppressor*
USB Cable
CF Plate
CF Slot Shading Sheet
IM Shied Plate
SEIKO EPSON
LAN Shading Sheet
CN801
Figure 4-34.
4-31
IM Board Assy.
EMI Suppressor*
(2)
(1)
(1)
(1)
(2)
CONFIDENTIAL
38))
USB Shading Sheet; B
Connector Shading Sheet
IM Fastening Plate
Revision:C