Section 5: Diagrams; Circuit Boards Location; Printed Wiring Board And Schematic Diagram Information; Reference Information - Sony TRINITRON KV-21FK120 Service Manual

Color television
Table of Contents

Advertisement

Available languages

Available languages

5-1. CIRCUIT BOARDS LOCATION

HK Board
KR Board
5-2. PRINTED WIRING BOARD AND
SCHEMATIC DIAGRAM INFORMATION
All capacitors are in µF unless otherwise noted. pF : µµF 50WV or less
are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms. k=1000, M=1000k
Indication of resistance, which does not have one for rating electrical
power, is as follows: Pitch : 5mm Rating electrical power :
1
1
1
/
W in resistance,
/
W and
4
10
: nonfl ammable resistor.
: fusible resistor.
: internal component.
: panel designation and adjustment for repair.
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B, unless
otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production tolerances.
All voltages are in V.
S : Measurement impossibillity.
: B+line.
: B-line. (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
KV-21FK120

SECTION 5: DIAGRAMS

A Board
/
W in chip resistance.
8
The components identifi ed by shading and
safety. Replace only with part number specifi ed.
The symbol
on the component side of the board. Replace only with fuse of the
same rating as marked.
Les composants identifi es per un trame et une marque
pour la securite. Ne les remplacer que par une piece portant le numero
specifi e.
Le symbole
remplace par une fusible de meme yaleur, comme maque.
The components identifi ed by X in this basic schematic
diagram have been carefully factory-selected for each set in
CV Board
order to satisfy regulations regarding X-ray radiation. Should
replacement be necessary, replace only with the value
originally used.
When replacing components identifi ed by Y, make the necessary
adjustments as indicated. If the results do not meet the specifi ed value,
change the component identifi ed by X and repeat the adjustment until
the specifi ed value is achieved.
(Refer to Section 3: Safety Related Adjustments on Page 21.)
When replacing the parts listed in the table below, it is important to
perform the related adjustments.
Part Replaced (Y)
DY, T585, CRT, IC001, IC561,
IC600, C506, C507, C508, T511,
L510, C588, L588, C566, C561,
C563, D567, D568, D566, PH602,
R567, R568, R565, R566, R562,
R563, R561, R528..........A Board

REFERENCE INFORMATION

RESISTOR
: RN
METAL FILM
: RC
SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW
NONFLAMMABLE WIREWOUND
: RS
NONFLAMMABLE METAL OXIDE
: RB
NONFLAMMABLE CEMENT
:
ADJUSTMENT RESISTOR
COIL
: LF-8L MICRO INDUCTOR
!
symbol are critical for
indicates a fast operating fuse and is displayed
!
sont critiques
indique une fusible a action rapide. Doit etre
Adjustment (X)
HV HOLD-DOWN
R565
CAPACITOR
: TA
TANTALUM
: PS
STYROL
: PP
POLYPROPYLENE
: PT
MYLAR
: MPS
METALIZED POLYESTER
: MPP
METALIZED POLYPROPYLENE
: ALB
BIPOLAR
: ALT
HIGH TEMPERATURE
: ALR
HIGH RIPPLE
KV-21FK120
37

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Trinitron rm-y194

Table of Contents