Page 1
Website http://biz.lgservice.com VACUUM CLEANER SERVICE MANUAL MODEL : V-CA484STQ CAUTION BEFORE SERVICING THE UNIT, READ THE "SAFETY PRECAUTIONS" IN THIS MANUAL. June, 2008 P/NO : MFL32023408 Printed in Korea...
SAFETY PRECAUTIONS BEFORE OPERATION THIS VACUUM CLEANER, READ THIS SERVICE MANUAL THOROUGHLY, AND OBSERVE EACH POINT CAREFULLY. 1. Change the paper bag or clean the cloth 4. Avoid sucking such materials as: bag in case the indicator moves toward 1) Liquid or wet dust : Clogging the ventilation holes, red.
SPECIFICATIONS MODEL V-CA484STQ POWER SOURCE ON RATING PLATE POWER CONSUMPTION ON RATING PLATE BODY SLIDE POWER CONTROL PUSH ON/OFF (BODY) PAPER CAPACITY CLOTH CORD LENGTH 6.3 m (1.0 mm NET WEIGH 5.4 kg PACKING WEIGHT 8.3 kg NET DIMENSION 300 460 242 (W D H)
DISASSEMBLY NOTE : Before attempting to service or adjust any part of the vacuum cleaner, disconnect the electrical power supply cord from the wall outlet. • Almost all the parts of this vacuum cleaner can be assembled with a screw driver and each connection component easily fits each other.
TROUBLE SHOOTING 1. SWITCH ON BUT MOTOR DOES NOT TURN Poor plug insertion. Insert again. Power cord cut. Repair or exchange. Interior lead wire cut. Exchange the lead wire. Motor (stator armature)coil Exchange the motor. cut or damaged. Poor contact carbon brush Exchange or repair.
Page 8
3. SWITCH OFF BUT MOTOR TURNS Poor connections. Repair Poor switch. Exchange the switch. 4. WEAK SUCTION POWER Exchange the carbon brush Carbon brush defaced. or the motor. Motor armature cut. Exchange the motor. Low rotation speed. Foreign matters attached to Remove the foreign the impeller matters.
Page 9
5. VIBRATION NOISES Loose parts. Secure firmly. Unbalanced motor Exchange or repair the assembly. motor. Foreign matters are Remove the foreign attached to the impeller. matters. Poor carbon brush Exchange the carbon brush rectification. or the motor. Armature is cut or foreign Exchange motor.