Electrical Adjustments - Sony DXA-WZ5 Service Manual

Stereo cassette deck amp
Table of Contents

Advertisement

DECK SECTION
0 dB=0.775 V
Note: Confirm each contents of this section first of all. If the results are
not satisfied, do the adjustment.
1.
Demagnetize the record/playback head with a head
demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjust.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual.
6.
The adjustments should be performed for both L-CH and R-
CH.
7.
Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Tape
Signal
P-4-A63J
10 kHz, –10 dB
Record/Playback Head Azimuth Adjustment
Procedure:
1.
Mode: Playback
test tape
P-4-A63J
(10 kHz, –10 dB)
set
2.
Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
within
L-CH
1 dB
peak
Output
level
R-CH
peak
Screw
position
SECTION 3

ELECTRICAL ADJUSTMENTS

Used for
Azimuth Adjustment
SPEAKER terminals (TM402)
L-CH, R-CH
level meter
+
within
1 dB
Screw
position
L-CH
R-CH
peak
peak
3.
Mode: Playback
test tape
SPEAKER terminals (TM402)
P-4-A63J
L-CH
(10 kHz, –10 dB)
L-CH
set
R-CH
R-CH
waveform of oscilloscope
in phase 45 °
good
4.
Repeat step 1 to 3 in playback (REV) mode.
5.
After the adjustments, apply suitable locking compound to the
pats adjusted.
DXA-WZ5
oscilloscope
V
H
90 ° 135 ° 180 °
wrong
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents