Download Print this page

Mitsubishi Electric PAR-SL94B-E User Instructions page 5

Wireless remote controller kit for ceiling suspended m

Advertisement

Wireless Remote Controller Kit
Function Selection
5
This setting is available only for Mr. Slim model. CITY MULTI model can be set by dip switch of indoor/outdoor
control circuit board. Refer to technical data of CITY MULTI model to set dip switch.
Each function can be set according to necessity using the remote controller.
The setting of function for each unit can only be done by the remote controller.
Select function available from the Table3. Function selection using wireless remote controller
is available only for refrigerant system with wireless function. Refrigerant address cannot
be specified by the wireless remote controller.
The article below describes how to set "LOSSNAY connectivity" into "supported
(indoor unit is not equipped with outdoor-air intake)" in Table 3 as an example.
Go to the function select mode
CHECK
Press the
button
(Start this operation from the status of remote controller display turned off.)
is lighted and "00" blinks.
CHECK
Press the temp
button
controller toward the receiver of the indoor unit and press the
Setting the unit number
Press the temp
button
the wireless remote controller toward the receiver of the indoor unit and
min
press the
button
Selecting a mode
Enter 03 to change the LOSSNAY connectivity setting using the
buttons. Direct the wireless remote controller toward the receiver
of the indoor unit and press the
Current setting number:
If a mode number that can not be recognized by the unit is entered,
3 beeps (3 beeps of 0.4 seconds duration)will be heard.
Reenter the mode number selecting.
If the signal was not received by the sensor or an error occurred during
transmission, you will not hear a beep or a "double beep" may be heard.
h
Press the
button again.
Selecting the setting number
Use the
and
to 02. Direct the wireless remote controller toward the sensor of the indoor
h
unit and press the
by the interrupted buzzer sounds and the blinks of operation indicator.
If a setting number that can not be recognized by the unit is entered, 3 beeps
(3 beeps of 0.4 seconds duration) will be heard (unit will beep only).
Reenter the setting number selecting.
If the signal was not received by the sensor or an error occurred during
transmission, you will not hear a beep or a "double beep" may be heard.
h
Press the
button again.
If the number that can not be set is input, the former setting number will be set.
To select multiple functions continuously
Repeat steps
and
Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit
and press the
button
NOTE : Whenever changes are made to the function settings after construction or
maintenance, be sure to record the added functions with an " ", in the
"Check" column provided on the chart.
for Ceiling Suspended models
twice continuously.
once to set "50". Direct the wireless remote
and
to set the unit number "00". Direct
.
h
button
.
1=1 beep (1 second)
2=2 beeps (1 second each)
3=3 beeps (1 second each)
buttons to change the LOSSNAY connectivity setting
button
.
to change multipul function settings continuously.
.
PAR-SL94B-E
CHECK
ON/OFF
FAN
MODE
VANE
CHECK
LOUVER
h
button
.
TEST RUN
SET
RESET
CLOCK
and
CHECK
CHECK
CHECK
CHECK
TEMP
AUTO STOP
AUTO START
h
min
E-133

Advertisement

loading