Page 1
1/3 inch High-Res Extended Dynamic Day/Night Camera CCWC1335-LP CCWC1335-MP Instruction Manual Fire Safety & Security Products Siemens Building Technologies...
Page 2
Dear Customer By selecting this SIEMENS product, you have chosen a professional device that guarantees the highest possible quality and reliability. We would like to thank you...
To ensure normal operation and to avoid EMC problems, the product must be installed according to the currently valid EMC installation guidelines. To meet the CE norms, enclosed EMI-cores should be applied to the Y/C and power cable (see chapter 7.1). Siemens Building Technologies Fire Safety & Security Products 03.2005...
EN 55022:1998 Class B EN 50130-4:1998 EN 61000-3-2 A2: 1998 EN 61000-3-3: 1995 The EU certificate of conformity is available for official inspection and is held at: Siemens Building Technologies SBT FSP DE Siemensallee 84 76187 Karlsruhe, Germany Ordering Data Designation Order No.
Page 7
Package contents Quickstart manual Siemens Building Technologies Fire Safety & Security Products 03.2005...
This is a fixed pattern, which may appear over the entire monitor screen when the camera is operated at a high temperature. Jagged picture When viewing stripes, straight lines, or similar patterns, the image on the screen may appear jagged. Siemens Building Technologies Fire Safety & Security Products 03.2005...
Wide dynamic OFF/ON (X 128) Gain control Selectable (OFF, Normal, Turbo); gain (up to 30 dB) Backlight compensation 6 area selectable: Center 1, Center 2,Up Half, Low Half, Middle Low, Middle High Siemens Building Technologies Fire Safety & Security Products 03.2005...
Page 10
OSD control 5 control keys on the side-panel of camera Default settings Default setting restored by pushing the DEFAULT button Remote control RS-485 Alarm IN Alarm OUT NC or NO selectable Siemens Building Technologies Fire Safety & Security Products 03.2005...
Camera Parts Back focus adjustment ring ① Back focus lock screw ② Tripod mount hole ③ IRIS connector ④ Power indicator ⑤ Video output ⑥ Power cord (or power terminal) ⑦ Siemens Building Technologies Fire Safety & Security Products 03.2005...
Select ENTER on the OSD; the menu will appear on the display and will disappear after 30 seconds if no action occurs. The shaded setting area means an item is selected and it keeps blinking. Siemens Building Technologies Fire Safety & Security Products 03.2005...
When set to this mode, the camera will remain in color mode. MANUAL When set to this mode, the camera will be switched to color or B/W mode manually according to a signal received at a terminal on the rear panel. Siemens Building Technologies Fire Safety & Security Products 03.2005...
We recommend using the D/N mode “MANUAL” when the camera is used with discrete IR illumination in order to prevent the continual switching between color and B/W mode that might occur with the D/N mode “AUTO”. Siemens Building Technologies Fire Safety & Security Products 03.2005...
WD „On“ activates the WD-mode that expands the dynamic range of the camera x128. NOTE: ELC-mode is for usage with fixed iris lenses! When activating WD-mode under extreme light-conditions, the video-output might look “artificial”; but the picture contents are much better visible. Siemens Building Technologies Fire Safety & Security Products 03.2005...
SENS UP GAIN NORMAL SYNC LL:000 NEXT EXIT CANCEL DEFAULT Fig. 7 GAIN Selection of GAIN: (NORMAL / TURBO / OFF) Move the cursor to the position shown in Fig. 7. Siemens Building Technologies Fire Safety & Security Products 03.2005...
NEXT EXIT CANCEL DEFAULT Fig. 9 This function is for selecting the backlight mode (OFF, BLC1, BLC2, BLC3, BLC4, BLC5, BLC6) Move the cursor to the position shown in Fig. 9. Siemens Building Technologies Fire Safety & Security Products 03.2005...
R and B (red and blue) values using the UP/ DOWN button. To exit, use the LEFT/ RIGHT to move the cursor between R and B, and press ENTER. Siemens Building Technologies Fire Safety & Security Products 03.2005...
Move the cursor to the position shown in Fig. 13. Use the LEFT/ RIGHT button to open this menu item, then move the cursor left and right to select the desired zoom factor. The maximum zoom factor is X2.6. Siemens Building Technologies Fire Safety & Security Products 03.2005...
1 SET CLR BACK CLEAR ALL In the submenu, the user can select ON or OFF for the privacy zone and set up to 8 blocks at any position on the screen. Siemens Building Technologies Fire Safety & Security Products 03.2005...
Press ENTER to perform back focus adjust. This function will force the iris of the AI lens to open fully and set the shutter speed temporarily to AUTO for easy back focus adjustment. Siemens Building Technologies Fire Safety & Security Products 03.2005...
N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 : < > □ - . , ; x / BACK CLEAR Fig. 19 CAMERA TEXT Siemens Building Technologies Fire Safety & Security Products 03.2005...
The camera address must be set correctly before installing the camera. Otherwise remote access may not be possible. 7.2.17.3 BAUD RATE This function is used to set the camera’s remote baud rate in the range from 2400 to 19200 bits per second. Siemens Building Technologies Fire Safety & Security Products 03.2005...
Select one of the 3 various protocols, depending on the type of remote connectivity, for remote OSD control camera setup: SIEMENS-B: When using the camera with bi-directional remote control under remote software and PC (remote software provides full parameter setup).