10. F No. & ND Light Quality Standard Data Input
RadarW
RadarW
RadarW
RadarW
RadarW
Correct the lens iris and the dispersion of the ND filter light quan-
tity.
Subject
Clear chart (All white)
(Zoom lens at WIDE end) (Note 2)
Adjustment Page
F
Adjustment Address
1C to 23
Note 1: Perform "Mechanical Shutter Adjustment" after this ad-
justment.
Note 2: With the ZOOM at WIDE end, set the distance where
the clear chart is shot with all-white signal.
Note 3: Check that the data of page: 0, address: 10 is "00".
Note 4: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) ZOOM .................................................................... WIDE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
01
2
6
30
01
3
6
01
BB
4
6
02
Note 5: The adjustment data will be automatically input to page:
F, address: 1C to 23.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
6
30
00
3
0
01
00
Procedure
Press PAUSE button. (Note 5)
Check the data changes to "01".
Procedure
Press PAUSE button.
DCR-TRV940/TRV940E/TRV950/TRV950E

11. LV Standard Data Input

Adjust the normal coefficient of the light value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Perform "AWB Standard Data Input" before this adjust-
ment.
Note 2: Check that the data of page: 0, address: 10 is "00".
Note 3: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 4: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
30
3
6
01
4
6
02
5
6
04
6
1
Note 5: The adjustment data will be automatically input to page:
F, address: 1A, 1B.
Note 6: Retry adjustment if the displayed data did not satisfy the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
04
3
6
30
4
0
01
6-31
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart
(Color reproduction adjustment
frame)
Displayed data of page: 1 (Note 4)
Adjusting remote commander
F
1A, 1B
0FE0 to 1020
Displayed data
Procedure
01
01
0D
Press PAUSE button. (Note 5)
Check the data changes to
"01".
1E
Check that the displayed data
(Note 4) satisfied the
specified value. (Note 6)
Procedure
00
Press PAUSE button.
00
00
00