Capacity Table; Combinations - Fujitsu AUU7RLF Design & Technical Manual

2/3/4 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

5.

CAPACITY TABLE

5-1.

COMBINATIONS

MODEL
: AOU18RLXFZ
Cooling
z
Combination of indoor unit
Room 1 Room 2
Total
7
7
14
7
9
16
7
9
16
7
12
19
7
12
19
9
9
18
9
9
18
9
12
21
9
12
21
Heating
z
Combination of indoor unit
Room 1 Room 2
Total
7
7
14
7
9
16
7
9
16
7
12
19
7
12
19
9
9
18
9
9
18
9
12
21
9
12
21
Note:
1. Specifications are based on the following conditions.
Power source of specifications: 230 V
7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h
2 or more indoor units should be connected.
Cooling: Indoor temperature of 80 °F(26.7 °C)DB/67 °F(19.4 °C)WB, and outdoor temperature of 95 °F(35 °C)DB/75 °F(23.9 °C)WB.
Heating: Indoor temperature of 70 °F(21.1 °C)DB/60 °F(15.6 °C)WB, and outdoor temperature of 47 °F(8.3 °C)DB/43 °F(6.1 °C)WB.
Pipe length: 24.6 ft.(7.5 m), Height difference: 0 ft.(0 m) [Outdoor unit - Indoor unit]
2. The total ability of connected a indoor unit is up to 21,000Btu from 14,000Btu.
3. Non-Ducted system combinations input are based on ASU wall mount models. The input of combinations including AUU cassette models may be a
little higher.
4. Ducted system combinations capacities are based on ARU slim duct units with the exception of 7,000Btu models are based on ASU wall mount
models.
Rated capacity
for each indoor unit
Type of
[kBtu/h]
indoor unit
Room 1
Room 2
Non-ducted
7.05
7.05
Non-ducted
7.09
9.11
ducted
7.09
9.11
Non-ducted
6.63
11.37
ducted
6.63
11.37
Non-ducted
9.00
9.00
ducted
9.00
9.00
Non-ducted
7.71
10.29
ducted
7.71
10.29
Rated capacity
for each indoor unit
Type of
[kBtu/h]
indoor unit
Room 1
Room 2
Non-ducted
9.20
9.20
Non-ducted
8.93
11.48
ducted
8.93
11.48
Non-ducted
8.11
13.89
ducted
8.11
13.89
Non-ducted
11.00
11.00
ducted
11.00
11.00
Non-ducted
9.43
12.57
ducted
9.43
12.57
- (02 - 06) -
Maximum capacity
for each indoor unit
Total capacity [kBtu/h]
[kBtu/h]
Room 1
Room 2
Min.
Rated
8.70
8.70
6.10
14.10
8.66
11.14
6.10
16.20
8.66
11.14
6.10
16.20
7.74
13.26
6.10
18.00
7.74
13.26
6.10
18.00
10.50
10.50
6.10
18.00
10.50
10.50
6.10
18.00
9.00
12.00
6.10
18.00
9.00
12.00
6.10
18.00
Maximum capacity
for each indoor unit
Total capacity [kBtu/h]
[kBtu/h]
Room 1
Room 2
Min.
Rated
10.35
10.35
6.80
18.40
9.58
12.32
6.80
20.40
9.58
12.32
6.80
20.40
8.99
15.41
6.80
22.00
8.99
15.41
6.80
22.00
12.20
12.20
6.80
22.00
12.20
12.20
6.80
22.00
10.46
13.94
6.80
22.00
10.46
13.94
6.80
22.00
Input power [kW]
Max.
Min.
Rated
Max.
17.40
0.50
1.30
1.64
19.80
0.50
1.44
1.81
19.80
0.50
1.49
1.86
21.00
0.50
1.43
2.06
21.00
0.50
1.48
2.11
21.00
0.50
1.44
2.06
21.00
0.50
1.49
2.14
21.00
0.50
1.44
2.06
21.00
0.50
1.49
2.14
Input power [kW]
Max.
Min.
Rated
Max.
20.70
0.52
1.50
1.97
21.90
0.52
1.77
1.92
21.90
0.52
1.73
1.90
24.40
0.52
1.87
2.10
24.40
0.52
1.83
2.08
24.40
0.52
1.87
2.10
24.40
0.52
1.83
2.08
24.40
0.52
1.88
2.10
24.40
0.52
1.84
2.08