Control Port Functions
● Output Expander (IC1804, TC74LCX574FT) Port Functions
Pin No.
Name
1
OE
2
D8
3
D9
4
D10
5
D11
6
D12
7
D13
8
D14
9
D15
10
GND
11
CK
12
Q7
13
Q6
14
Q5
15
Q4
16
Q3
17
Q2
18
Q1
19
Q0
20
Vdd
Function
IO_ENB
D8
D9
D10
D11
D12
D13
D14
D15
GND
ADD1_CS
MUTE
CG-FILT
FILT_480P/575P
CABLE_SW
PC/AV_SW
S/CV_SW
MONIT_OUT
PC1/PC2_SW
Power Supply +3.3V
Output Port Chip Select
Mute Output
Filter-on at RGB signal
Filter-on at 480p/575p signal
PC/AV Mode switch
S-Video/Video switch
PC2 Monitor out Mode
PC1/PC2 Mode switch
-46-
I/O
I
I
I
I
I
I
I
I
I
-
Enable = L
I
Mute-on=H
O
O
O
O
PC=H
O
S-Video=H
O
PC2 MONITOR=H
O
PC1=H
O
-