Bosch MIC612 Installation Manual page 46

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

46
en | On-Screen Display (OSD) Menus (Bosch Protocol)
Exit...
1. Rule 1
2. Rule 2
3. Rule 3
4. Rule 4
5. Rule 5
6. Rule 6
7. Rule 7
8. Rule 8
9. Rule 9
10. Rule 10
11. Rule 11
12. Rule 12
Rule Setup Submenu Choices:
Rule Setup
Displays the status of rules and lets you add new rules or modify an existing rule.
Rule 1-12
Displays the status of a rule on the right side of the menu. Rule status options:
Option
Enabled The rule inputs and outputs are properly defined and the rule is
Disabled The rule inputs and outputs are defined but the rule is turned off.
Invalid
Empty
Selecting a Rule number provides access to its configuration menu. The Rule # Menu allows
you to configure a rule from previously-defined alarm inputs and outputs. Once an alarm is
configured with valid inputs and outputs, it can be turned on or off (enabled or disabled)
through its configuration menu.
Rule # Choices:
Enabled
Turns the rule on or off after its inputs and outputs have been defined.
YES to enable or NO to disable (default setting)
Input
Toggles through a list of valid inputs set in the Alarm I/O Setup > Inputs Setup Menu that
define the rule's inputs. A rule can have up to four (4) inputs.
Ilnputs which were set in the Inputs Setup Menu include Aux On/Off (1-99), Shot, and NONE
(default setting).
F.01U.249.416 | 1.1 | 2012.03
Rule Setup...
Enabled
Disabled
Invalid
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Focus / Iris: Select
Description
turned on.
The rule has a missing or invalid input or output.
(Default setting) The rule has no inputs or outputs defined.
Installation Manual
Rule 1
Exit...
Enabled
YES
Input:
NONE
NONE
NONE
Output:
OSD
Shot 2
Alarm Relay
2 sec
NONE
Right / Left: Select Period Time
Focus / Iris: Select Type
MIC612 Thermal Camera
Bosch Security Systems, Inc.

Advertisement

Table of Contents
loading