Page 1
(TAC0057) – SUMMARY – 43A10, 43AX60 are the same as 50A60 except for the parts and bus data of micro-processor, Con- vergence ajustment and Mechanical disassembly tabled on back of this sheet. Use this service manual together with the service manual of 50A60, 50A50, 55A60, 61A60 (File No.
Page 2
SETTING & ADJUSTING DATA DIFFERENCES SERVICE MODE ADJUSTING ITEMS AND DATA IN THE SERVICE MODE: Item Name of adjustment Preset Data V-HEIGHT V-S CORRECTION PICTURE WIDTH V-LINEARITY PARA E-W PARABOLA(DPC) TRAP TRAPEZIUM Table-2 DESIGN MODE ADJUSTING ITEMS AND DATA IN THE DESIGN MODE: Item Name of adjustment Preset Data...
CONVERGENCE ADJUSTMENT Adjust convergence from center to circumference in order. 1. Select the adjustment mode following the steps on page 9 of original service manual. RCUT KEY FUNCTION IN THE CONVERGENCE ADJUSTMENT: Up : 2 button Selet Green color: 3 button Left : 4 button 2.