Mitsubishi Electric PUHZ-W50VHA-BS Service Manual page 42

Air to water heat pump
Hide thumbs Also See for PUHZ-W50VHA-BS:
Table of Contents

Advertisement

PUHZ-HW112YHA(-BS)
PUHZ-HW112YHA2(-BS)
PUHZ-HW112YHA2R1(-BS)
PUHZ-HW112YHA2R3(-BS)
Water OUT
Plate HEX
TH32
Water IN
TH6
Symbol
Part name
COMP
Compressor
H/P SW
High pressure switch (63H)
L/P SW
Low pressure switch (63L)
Plate HEX
Plate Heat Exchanger
REV/V
Reversing (4-way) valve (21S4)
STOP VALVE
Stop valve
CHECK/V
Check valve
P-Sensor
Pressure sensor (63HS)
P/B
Power board
LEV-A
Linear expansion valve -A
LEV-B
Linear expansion valve -B
LEV-C
Linear expansion valve -C
TH33
Suction temperature thermistor
TH32
Inlet water temperature thermistor
TH3
Liquid temperature thermistor
TH4
Discharge temperature thermistor
TH6
Plate HEX liquid temperature thermistor
TH7
Ambient temperature thermistor
TH8
Heatsink temperature thermistor
TH34
Comp. surface temperature thermistor
Power Receive
Power Receiver
r
Heat interchange circuit
HIC
*1 PUHZ-HW112YHA(-BS), PUHZ-HW140YHA(-BS), PUHZ-HW140VHA(-BS)
*2 PUHZ-HW112YHA2(-BS), PUHZ-HW140YHA2(-BS), PUHZ-HW140VHA2(-BS), PUHZ-HW140VHA2R1-BS
*3 PUHZ-HW112YHA2R1(-BS), PUHZ-HW140YHA2R1(-BS), PUHZ-HW140VHA2R1, PUHZ-HW140VHA2R2-BS,
PUHZ-HW112YHA2R3(-BS), PUHZ-HW140YHA2R3(-BS), PUHZ-HW140VHA2R3(-BS)
OCH439H
PUHZ-HW140YHA(-BS)
PUHZ-HW140YHA2(-BS)
PUHZ-HW140YHA2R1(-BS)
PUHZ-HW140YHA2R3(-BS)
STOP VALVE
REV/V
CHECK/V
Strainer
(#100)
Power
Receiver
Strainer
(#100)
LEV-B
Strainer(#100)
DC inverter scroll compressor (Mitsubishi Electric Corporation)
For protection (OFF:4.15MPa)
For protection (OFF:-0.03MPa)
ACH50-50 (Alfa Laval) (*1)/ACH70-52 (Alfa Laval) (*2)/
MWA2-46LM (MITSUBISHI) (*3)
Change the refrigerant circuit (Heating / Cooling) and for Defrosting
For refrigerant charge
High pressure / Low pressure / For production test use
For calculation of the condensing temperature from high pressure
Inverter power board
Heating:Secondary LEV
Heating:Primary LEV
For HIC (heating only)
For LEV control
For freeze protection and for compressor frequency control
Heating:Evaporating temperature
For LEV control and for compressor protection
Heating:Sub cool liquid temperature
For fan control and for compressor frequency control
For power board protection
For compressor protection
For accumulation of refrigerant
For high heating capacity
P-Sensor
CHECK/V
H/P SW
L/P SW
MUFFLER (only
TH33
TH4
TH34
(only for
R3 models)
Strainer
INJ Port
(#100)
COMP
HIC
LEV-C
Detail
Cooling:Primary LEV
Cooling:Secondary LEV
Cooling:Sub cool liquid temperature
42
PUHZ-HW140VHA(-BS)
PUHZ-HW140VHA2(-BS)
PUHZ-HW140VHA2R1(-BS)
PUHZ-HW140VHA2R2-BS
PUHZ-HW140VHA2R3(-BS)
TH7
Distributor
HW·HA)
Strainer(#100)
TH8
P/B
LEV-A
Refrigerant flow in heating
Refrigerant flow in cooling
Cooling:Evaporating temperature
TH3