Flow Control, No Timeout
Two-Direction Flow Control
Character-Based Flow Control
with Timeout
RS232 Timeout
When using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host.
Set the length (in milliseconds) for a timeout by scanning the bar code below, then setting the timeout (from 1-65535 milli-
seconds) by scanning digits from the
XON/XOFF
With XON/XOFF On, standard ASCII control characters can be used to tell the scanner to start sending data or to stop
sending data. When the host sends the XOFF character (DC3, hex 13) to the scanner, data transmission stops. To resume
transmission, the host sends the XON character (DC1, hex 11). Data transmission continues where it left off when XOFF
was sent. Default = XON/XOFF Off.
XON/XOFF On
2 - 26
Programming
Chart, then scanning Save. Default = 1000 ms (1 second).
RS232 Timeout
Character-Based Flow Control,
No Timeout
Flow Control with Timeout
* XON/XOFF Off