Sign In
Upload
Manuals
Brands
Haier Manuals
Heat Pump
AU112FYCRA(HW)
Haier AU112FYCRA(HW) Manuals
Manuals and User Guides for Haier AU112FYCRA(HW). We have
1
Haier AU112FYCRA(HW) manual available for free PDF download: Service Manual
Haier AU112FYCRA(HW) Service Manual (113 pages)
ATW
Brand:
Haier
| Category:
Heat Pump
| Size: 16.19 MB
Table of Contents
Table of Contents
2
Outdoor Units Lineup
3
Nomenclature
4
Energy Saving and High Reliability
5
Flexible and Convenient Control
5
Integrated and Compact Design
5
Feature
5
Air Cooled Coils
6
Fan Motor
6
Hydraulic Module
6
Description of Main Components
6
Specifications
8
Dimensions
11
Piping Diagram
13
Wiring Diagram
16
Electric Characteristics
18
Cooling Capacity
19
Capacity Tables
19
Ethylene Glycol Solutions
25
Operation Limits Delivery-Leaving
25
Fouling Factors
26
Water Pressure Drop
27
Sound Level
29
Installation
30
Safety
31
Transporting Management Requirements
33
Storage Requirements
33
Loading and Unloading Requirements
33
Loading and Unloading/Transporting Management/Storage Requirements
33
Unpacking Inspection
34
Inspection on Installation Environment
34
Safety Principles of Installation
34
Electrical Safety Requirements
34
Fixing
35
Post-Installation Inspection Items and Test Run
35
Maintenance Instructions
35
Maintenance Precautions
35
Leak Detection Methods
36
Maintenance Site Requirements
36
Inspection on Maintenance Environment
36
Safety Principles
37
Maintenance Requirements
37
Maintenance of Electrical Components
37
Maintenance of Intrinsically Safe Elements
37
Refrigerant Charging Procedures
38
Welding
38
Removal and Vacuumizing
38
Scrapping
39
Precautions for Handling Units for Use with R32
42
Before Installing the Unit
42
Before Installing (Relocating) the Unit or Performing Electric Work
43
Before the Test Run
43
General Information
44
Combination and Options
44
Accessories
44
Manual Handling
45
Hoisting Method
45
Transportation and Lifting
45
Installation Instruction
46
Installation Place Selection
46
Installation and Maintenance Space
47
Multi-Unit Installation
47
Back and Side
47
Front and Back
47
Precautions on Installation
48
Foundation Work
48
Drain Work of the Outdoor Unit
49
Requirements and Recommendations for the Hydraulic Circuit
49
Hydraulic Circuit
50
Air Purging
50
Anti- Freezing
50
Minimum Flow Rate
51
Filter
51
Expansion Tank
51
Heat Loss
51
Water Control
52
Connection
53
Electric Wiring and the Application
53
Inspect
53
General Check
53
Communication Wiring Figure
54
Power Wiring Figure
54
Outdoor Power Source and Power Cable
55
Communication Wire for Wired Controller
55
Outdoor Unit Electrical Wiring Diagram
56
PCB Photo
57
Bridge Instruction
58
BM1 Introduction
58
BM2 Introduction
58
Dip Switch Setting
58
Digital Tube Display
59
Preparing for First Start up
61
Operating Characteristics
61
Compressor Start up Delay
61
Startup & Running & Maintenance
61
Routine Maintenance
62
Frost Prevention Alarm
62
Water Flow Alarm
62
Fan Speed Control
62
Chemical Washing
63
Refrigerant Gas Content
63
Shutting down for Long Periods
63
Interface Display
64
YR-E27(Optional Wired Controller)
64
Key and Icon
65
Basic Function Description
66
Operation
66
Setting Special Functions
67
Child Lock
67
On/Off
67
Forced to Start Pump (for Debugging)
67
Timer
71
Week and Clock Function Settings
73
Dip Switch
73
Wired Controller Wiring Instruction
73
Error Code
75
Temperature Sensor Failure
76
If Sensor Terminal Is Fixed Well
76
Troubleshooting
76
System Water Flow Protection
77
LED Displays 08E/10E
77
High/Low Pressure Sensor Failure
78
High Pressure Switch Failure
79
Outdoor EEPROM Failure
80
If the EEPROM Is Fixed Well
80
Low Pressure too Low and Compression Ratio too High
82
Compression Ratio too Low
83
High Pressure too High Failure
84
Discharging Temp. Sensor Td too Low Protection
85
Communication with Inverter Module Failure
86
CT Current too Low or Current Sensor Failure
87
CT Current too High
88
DC Motor Blocked
89
Pressure Difference between High Pressure and Low Pressure Is Abnorma
90
Transient over Current in IPM Module Rectifier Side Hardware
91
Compressor Current Protection
91
IPM Module Hardware over Current
91
Transient over Current in IPM Module Rectifier Side Software
91
Compressor out of Control
92
The Compressor Start Failure
92
Radiator Temp. of Transducer too High
93
IPM Module Temp. too High
93
Protection of Overload
94
Voltage too Low of DC Bus Line of Transducer
95
Voltage too High of DC Bus Line of Transducer
96
Communication Abnormal between Transducer
97
Transducer over Current (Software Protection)
98
Current Detection Circuit of Transducer Is Abnormal
99
Power Supply of Transducer Abnormal
100
Power Supply of Inverter Board Is Abnormal
101
Radiator Temp. Sensor of Transducer Abnormal
102
APPENDIX Sensor Resistance Table
103
Advertisement
Advertisement
Related Products
Haier MRVII-S AU28FHEPA
Haier MRVII-S AU282FHERA
Haier MRVII-S AU482FIERA
Haier AU48NFIERAG
Haier AU60NFIERAG
Haier AU482FIERAG
Haier AU082FYCRA(HW)
Haier AU162FYCRA(HW)
Haier GE APPLIANCES AUH2436ZGDA
Haier GE APPLIANCES AUH4860ZGDA
Haier Categories
Air Conditioner
Washer
Refrigerator
TV
Freezer
More Haier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL