Mitsubishi Electric Artisan MELSEC-QnAS Manual (198 pages)
General-purpose Programmable Controllers, Large/Small
Brand:
Mitsubishi Electric
| Category:
Controller
| Size: 4.85 MB
Table of Contents
Safety Precautions
4
When Replacing Ans (Small Type) Series with L Series
10
Conditions of Use for the Product
16
Revisions
17
Introduction
18
Table of Contents
19
Replacement Options and Module Selection Guide
21
Part I : Hardware
26
1 Comparison of Base Mounting Area
27
Comparison of A/Qna (Large Type) Series and Q Series Base Unit Mounting Area
27
Comparison of Ans/Qnas (Small Type) Series and Q Series Base Unit Mounting Area
29
Comparison of Ans/Qnas (Small Type) Series and L Series Mounting Area
31
2 Utilizing External Wiring
32
Replace A/Qna (Large Type) Series with Q Series
32
Install Terminal Block Converter Module and Terminal Module Externally
32
Replace Using Q Series Large Type Base Unit and Q Series Large Input/Output Module
39
Replacement Utilizing a (Large Type) Upgrade Tool (Manufactured by Mitsubishi Electric Engineering Co., Ltd.)
46
Replace Ans/Qnas (Small Type) Series with Q Series
50
Replace Using Ans Size Q Series Large Type Base Unit
50
Replace Using a (Small Type) Upgrade Tool (Manufactured by Mitsubishi Electric Engineering Co., Ltd.)
51
Replace Ans/Qnas (Small Type) Series 200 V AC Input Module A1SX20 Without Changing I/O Address
56
Replace Ans/Qnas (Small Type) Series with L Series
59
Replace Using a (Small Type) Upgrade Tool (Manufactured by Mitsubishi Electric Engineering Co., Ltd.)
59
Replace Ans/Qnas (Small Type) Series 200 V AC Input Module A1SX20 Without Changing I/O Address
62
Replace A0J2 with Q Series
63
Replace A0J2(H) Systems with Q Series Using A0J2 Upgrade Tool
67
Upgrade to MELSECNET/H (Remote I/O Network) System Using A0J2 Upgrade Tool
71
Replace MELSECNET/MINI Compact Type Remote I/O Modules with CC-Link
73
3 Replacement Utilizing Existing Modules
75
Replace A/Qna (Large Type) Series with Q Series
75
Utilize
75
Utilize Existing I/O Modules and Extension Base Unit with Q Series CPU (Use QA Conversion Adapter)
77
Replace Ans/Qnas (Small Type) Series with Q Series
79
Utilize
79
Replace Main Base Unit with Q Series and Use Existing Extension Base Unit and Modules in It (Use QA1S Conversion Adapter)
82
Utilize Existing a (Large Type) and Ans (Small Type) Modules Without Changing I/O Addresses
83
4 Replacement of MELSECNET Network System
85
Replace MELSECNET(II) with MELSECNET/10
85
Replace MELSECNET(II) Coaxial Loop with MELSECNET/10 Coaxial Bus System
85
While Retaining Existing a Series Cpus
85
Upgrade to MELSECNET/H Network System Utilizing Existing MELSECNET/B Twisted Pair Cable
87
Replace One of a Series Stations with Q Series While Retaining MELSECNET(II)
91
Replace a Series Local Station with Q Series
91
Replace a Series Master Station with Q Series
93
Replace MELSECNET Containing a Remote I/O Station with MELSECNET/H
95
Gradual Replacement of MELSECNET/10 Remote I/O Net
100
Replace MELSECNET/MINI(-S3) with CC-Link
103
Replace A2CCPU with Q Series CPU and CC-Link (Using A2C Shape CC-Link I/O Modules)
103
Replace MELSECNET/MINI(-S3) with CC-Link (Using Wiring Conversion Adapter)
105
Replace MELSECNET/MINI(-S3) Remote I/O Station (Building Block Type: AJ72PT35) with MELSECNET/H Using the Existing External Wiring
107
Replace
111
5 Replacing with Replacement Dedicated Modules
113
Replace High-Speed Counter Modules (AD61(S1)) with Q Series Modules
113
Replace DC Input Modules with 6 Ma Rated Input Current (QX41-S2, QX81-S2)
119
Replace Analog Output Positioning Module (AD70/A1SD70) with Q Series
121
6 Replacement Utilizing Spare Part
125
Use Ans (Small Type) Modules as Spare Parts for Existing a (Large Type) Series Modules
125
Use Ans (Small Type) I/O Modules as Spare Parts for a (Large Type) Input/Output Modules
126
Use Ans (Small Type) Module as Spare Parts for a (Large Type) Computer Link Module
128
Use Q Series Modules with Ans/Qnas Series Utilizing Ans-Q Module Conversion Adapter
130
Part II : Programming
132
7 Precautions for Utilizing ACPU Programs in QCPU
133
Replace Instructions with Different QCPU Instruction Format (Excluding Anacpu/Anucpu Dedicated Instructions)
134
Instructions that Use Accumulators (A0, A1)
134
ASCII Code Conversion Instruction "ASC
138
Replace Anacpu/Anucpu Dedicated Instructions
141
Use Index Register as a 32-Bit (2-Word) Device
145
Utilize SFC Programs (Replace MELSAP-II with MELSAP3)
149
Method for Maintaining Existing Addresses When Replacing MELSECNET/MINI(-S3) with CC-Link
155
Replace Pulse Catch Module
157
Replace with LCPU Built-In I/O Pulse Catch Function
157
Replace with QCPU Interrupt Module
159
Part III : Application
160
8 Utilize Existing ACPU Data
161
Replace AD75(P/M) with QD75(P/D/M/MH) While Utilizing Existing Positioning Parameters and Data
161
Procedures for Replacing When File Registers Are Used in Blocks
165
Replace Without Changing File Register Numbers
165
Replace by Putting File Registers Forward
168
Copy Device Memory Data
169
9 Utilize A/Qna -> Q Conversion Support Tool
171
Utilize Programs of PC Type Incompatible with GX Developer
171
A/Qna -> Q Conversion Support Tool
174
10 Notes for Selection of Replacement Modules
183
Select Replacement Module for DC Input Module
183
Notes for Selection of Replacement for Triac Output Module AY22
187
11 Notes for Replacement of Network (MELSECNET(II))
189
Cpus Compatible with Networks (MELSECNET(II), MELSECNET/10 and MELSECNET/H)
189
System Configuration for MELSECNET/10 and MELSECNET/H (PLC to PLC Network)
189
System Configuration for Existing MELSECNET(II) in Combination with Q Series CPU
190
System Configuration for MELSECNET/10 and MELSECNET/H (Remote I/O Network)
190
System Configuration for Redundant System Network
191
Warranty
193
Advertisement
Advertisement
Related Products
Mitsubishi Electric Artisan MELSEC-Q Series
Mitsubishi Electric Artisan MELSEC-A
Mitsubishi Electric Artisan MELSEC-QnA
Mitsubishi Electric Artisan MELSEC-AnS
Mitsubishi Electric Artisan MELSEC-L Series
Mitsubishi Electric A1SJ61BT11
Mitsubishi Electric MELSEC-A A2CCPUP21
Mitsubishi Electric AL2-MR-D Series
Mitsubishi Electric AnyWire ASLINK
Mitsubishi Electric AJ72T25B
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL