Sign In
Upload
Manuals
Brands
Siemens Manuals
Switch
7XV5550-0xA00 Series
Siemens 7XV5550-0xA00 Series Manuals
Manuals and User Guides for Siemens 7XV5550-0xA00 Series. We have
1
Siemens 7XV5550-0xA00 Series manual available for free PDF download: Manual
Siemens 7XV5550-0xA00 Series Manual (52 pages)
Active Mini-Starcoupler
Brand:
Siemens
| Category:
Switch
| Size: 0.64 MB
Table of Contents
Table of Contents
3
1 Application and Short Functional Description
9
Technical Features
10
Interfaces
10
Setting Parameters
11
Master and Slave-Interfaces
11
Master-Interfaces
12
Slave-Interfaces
12
Baudrates
12
Data Format
12
Channel Selection During the Operation
12
Disconnection between Master- and Slave-Interface
13
Internal Memory for the Data-Transfer
13
Cascading Several Mini-Starcouplers
14
Mini-Starcoupler as Master-Device
14
Further Mini-Starcouplers as Slave-Devices
14
2 Technical Datas
15
Hardware Features
15
Safety Tests
16
EMC Tests
17
Mechanical Stress Tests
18
Climatic Stress Tests
18
Dimensions
19
3 Ordering Code
19
4 Describtion of the Device and It´s Interfaces
20
General Description
20
Position and Assignment of the Terminals
20
Auxilliary Voltage X2
20
Alarm Contact X7
20
Optical Interfaces Tx/Rx
20
RS232 Operating Interface X1
21
RS485- Cascading Interface X5
22
DIP-Switches S1 and S2
22
Terminal Assignment
23
Auxilliary Voltage Terminals X2
23
Alarm Relay Terminals (Live Contact) X7
23
RS232-Interface X1
23
RS485-Interface X5
24
Led's
24
Green LED "RUN
24
Yellow LED "MASTER
24
Yellow LED "SLAVE
24
Setting of the DIP-Switches
25
5 Installation and Commissioning
26
Reference to Installation
26
Connection
26
Voltage for Operation - Auxilliary Voltage
27
Alarm Relay Terminals X7
27
Fibre Optic (FO) Connections
27
RS232 Connection
28
Commissioning
28
Maintenance
28
6 Modes of Operation
29
How to Activate the Operation Mode
29
How to Select the Active Transmission Mode
29
Passiv Transmission Mode
30
Termination of the Active Transmission Mode
30
Time out Conditions
30
Test Aid for the Data Connection
31
Activation of the Setting Mode
31
With DIGSI - Cable 7XV5100-4 (Bridged between Pin 7-8)
31
With Zero-Modem Cable (Not Bridged between Pin 7-8)
32
With Standard Parameters 9600 Baud, 8N1 (Recommended)
32
Setting of the Interfaces
33
With the Terminal Program "Hyper-Terminal
33
The Main Setting Dialogue / Change Language
34
Changing the Parameters of a Port (Interface)
35
Saving Parameters
38
Termination of the Setting Mode
38
7 Change the Firmware in the Device
39
Warnings
39
How to Change the Firmware
39
8 Applications Together with Siprotec Relays
40
SIEMENS-Relays of Version 1/2 Together with DIGSI V3
40
8.1.1 Functional Limitations with V1 / V2 Protection Devices
44
SIEMENS-Relays of Version 1/2 and 3 Together with DIGSI V3
45
8.2.1 Operation with DIGSI 4.3X
46
SIEMENS-Relays of Version 1/2/3 and SIPROTEC 4 Relays Together with DIGSI V3 or DIGSI 4
48
8.3.1 Operation with DIGSI 4.3X
49
Advertisement
Advertisement
Related Products
Siemens 7XV5655-0BA00
Siemens 7XV5655-0BA00/BB
Siemens 7XV75
Siemens 7ML5732
Siemens 7ML5733
Siemens 7LF4 521-0
Siemens 7LF4 521-2
Siemens 7ML701
Siemens 7ML702
Siemens 7ML5735
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL