en Installation Guide
1 Overview
The ISC-FPB1-W30DS, ISC-FPB1-W60DS, and ISC-FPB1-W90DS are
dual-beam photoelectric detectors designed for indoor and outdoor
applications. Consisting of a separate transmitter and receiver, they
are designed to activate an alarm when an intruder passes within the
direct line of sight between the transmitter and receiver.
1.1 Coverage range:
Model
Outdoor
Indoor
ISC-FPB1-W30DS
30 m/100 ft
60 m/200 ft
ISC-FPB1-W60DS
60 m/200 ft
120 m/400 ft
ISC-FPB1-W90DS
90 m/300 ft
180 m/600 ft
1.2 Accessories:
Accessories
BH12T
10.5V-28VDC Heater
MP1
Metal pole, 1 m (3 ft)
MP2
Metal pole, 1.2 m (4 ft)
MP3
L -curved metal pole
© 2014 Bosch Security Systems, Inc.
9
2
3
4
5
1
7
6
11
11
10
Figure 1.1 Transmitter and receiver overview
Callout - Description
1 - Cover
7 - Optical Alignment scope
2 - Wiring terminals
8 - Mounting plate
3 - LED indicators
9 - Wire entry
4 - Tamper switch
10 - Cover securing screws
5 - Vertical adjustment screw
11 - Device securing screws
6 - Twin lens
Figure 1.2 Transmitter/receiver dimensions
Callout - Description
1 - Knockout
4 - Pole mount bracket
2 - Center of the upper beam
5 - Pole mount clamp
3 - Center of the lower beam
6 - Pole diameter between 38-42.7 mm/1.49-1.68 in
2 Installation
2.1 Wall mount installation
1.
Remove the cover and the mounting plate. Refer to Figure 2.1.
2.
Fasten the mounting plate by drilling holes, and then installing the screws, and fastening the
mounting plate onto the wall.
1.
2.
Figure 2.1: Fastening the mounting plate and removing the cover.
3.
Route the wire through by inserting the wire between the foam sealing block. Verify the foam
9
seals against the wires to prevent insects from entering the device. Refer to Figure 2.2.
8
2
4.
Attach the sensor to the mounting plate, and then fasten the screws.
4
3.
9
7
11
Figure 2.2: Inserting the wire and fastening the mounting plate to the sensor.
5. Close the sensor by fastening the device fixing screws, and then close the cover.
2.2 Pole mount installation
1.
Route the wire through the wire hole of the pole.
2.
Attach the bracket to the pole with the pole mount clamp.
1.
Figure 2.3: Routing the wire through the pole and attaching the bracket to the pole holder.
3 Wiring
3.1 Terminal strip overview
5
Figure 3.1: Terminal strip overview and wiring example.
Callout - Description
1 - Transmitter
2 - Receiver
3 - Tamper (normally closed)
4.
2.
CAUTION!
Ensure that the pole mount installation is secure and stable. Failure to do so may result
in personal injury, or damage the device.
1
6
3
5
4 - Alarm contacts
5 - Power (non-polarized)
6 - FREE (unused)
2
4
3
F.01U.282.674 | 05 | 2014.10 | 1

Advertisement

loading

Summary of Contents for Bosch Photobeam 3000 ISC-FPB1-W30DS

  • Page 1 4 - Alarm contacts 2 - Receiver 5 - Power (non-polarized) 3 - Tamper (normally closed) 6 - FREE (unused) Figure 2.1: Fastening the mounting plate and removing the cover. © 2014 Bosch Security Systems, Inc. F.01U.282.674 | 05 | 2014.10 | 1...
  • Page 2 “zig-zag” pattern to disrupt the beam Bosch Security Systems, Inc. product manufacturing dates Callout - Description Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. Web site at: http://www. signal. boschsecurity.com/datecodes/.

This manual is also suitable for:

Photobeam isc-photobeam fpb1-w60dsPhotobeam isc-fpb1-w90ds