3.2 Wiring lengths
Each value in the table below represents the maximum wiring distance (one way) when using
DC12V or DC24V power source. When installing 2 or more sets on one wire, obtain the maxi-
mum length by dividing the maximum wire length listed below by the number of sets installed.
When using a thicker wire gauge (19 AWG or 0.9 mm wire), use relays for connection. It is not
possible to connect directly to the terminal inside of the detector.
Maximum wiring distance
Wire Gauge
ISC-FPB1-W30DS
ISC-FPB1-W60DS
AWG
Ø mm
12V
24V
12V
22
0.65
270m/885ft
1980m/6500ft
210m/670ft
1890m/6200ft
19
0.90
530m/1738ft
4770m/15650ft
410m/1350ft
3690m/12105ft
16
1.20
970m/3182ft
8730m/28701ft
750m/2460ft
6750m/22150ft
Table 3.2: Wire lengths
CAUTION!
Ensure that proper safety precautions such as powering off the device, and/
or protecting the wire from outdoor elements is adhered to. Failure to do so
may result in personal injury, or damage to the device.
4 Beam spread
The optical path forms as the beam spreads when it is reflected against an adjacent reflec-
tive surface such as a wall. Reflection of this beam may prevent a true alarm condition even if
the beam from the transmitter to the receiver is interrupted. The beam from another detector
may affect and cause malfunction when a multiple number of detectors are installed.The beam
spread angle of this unit is about ±1°. Refer to the figure and table below to determine the
installation position and distance to be used when installing a multiple number of units.
Figure 4.1: Beam spread distances
Distance and (approximate) beam spread
Distance (A)
Beam spread width (B)
Distance (A)
15m/49 ft
0.5m/1.6 ft
90m/295 ft
30m/98 ft
1.0m/3.3 ft
120m/394 ft
60m/197 ft
2.0m/6.6 ft
180m/591 ft
5 Sensitivity adjustment
Figure 5.1: Sensitivity adjustments
Callout - Description
1 - Fast running at full speed
3 - Normal walking
2 - Walking with quick steps
4-5 - Slow motion
© 2014 Bosch Security Systems, Inc.
6 Optical axis alignment
You can align an optical axis two ways: with a level LED and/or with a
tester.
6.1 Using an optical alignment
6.1.1 Coarse adjustment
Use the horizontal adjustment turntable and the vertical adjustment screw to
aim the optics at the detector scope view finder.
ISC-FPB1-W90DS
24V
12V
24V
170m/560ft
1530m/5020ft
340m/1115ft
3060m/10040ft
620m/2035ft
5580m/18310ft
Figure 6.1: Level LED adjustment
Callout - Description
1 - Turntable
2 - Verticle adjustment screw
6.2 Using a tester
6.1.2 Fine adjustment
Insert the volt meter tips into the test terminals of the receiver to check the
voltage. If the value is 1.9V or more, the adjustment is completed. If it is less
than 1.9V, adjust the transmitter and receiver until 1.9V or more voltage is
obtained. A voltage level of 2.2V or above is ideal.
Beam spread width (B)
3.0m/9.8 ft
4.0m/13.1 ft
6.0m/19.7 ft
Figure 6.2: Using the test terminals
Callout - Description
1 - Test terminals
7 Operational check
Perform the following to test the operation of the detector.
7.1 Alarm operation
1.
To check the alarm operation, walk along the assumed intrusion path near
the transmitter and receiver, in a "zig-zag" pattern to disrupt the beam
signal.
2.
Check that the alarm LED lights up and the control panel receives the
alarm signal when the beam is interrupted.
7.2 Tamper operation
1.
Check that the control panel receives a tamper alarm when either of the
transmitter and/or receiver covers are open.
8 Maintenance
Inspect the device regularly for proper functionality. Check the following:
Tester voltage level is above 1.9V.
Power input voltage is between DC 10.5V and 28V.
Alarm and tamper outputs are functional.
9 Troubleshooting
Problem
False
Obstacle in the line of sight.
alarms
Optical alignment is incomplete.
Unstable installation.
Distance between transmitter and receiver
exceeds maximum range.
Interference from another transmitter.
Electrical noise nearby
Sunlight penetrates receiver within +/- 3°.
No
A reflective surface is parallel with the
alarm
beam.
Reflective floor surface.
Interference from another transmitter.
3 - Scope view finder
10 Certifications
Region
Certification
US
UL 639 Listed - Intrusion Detection Units and Systems
11 Specifications
Product Name
Model
Max. outdoor range
Max. indoor range
Transmitter current draw at 25
Receiver current draw at 25
Power
Sensitivity
Horizontal adjustability
Vertical adjustability
Alarm output
Tamper output
Operating Temperature (Relative humidity)
Storage Temp/Humd
IP rating (indoor/outdoor)
Weight (transmitter and receiver each)
Dimensions
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. Web site at: http://www.
boschsecurity.com/datecodes/.
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
Cause
Solution
Remove obstacle.
Perform optical alignment to obtain 1.9V or higher.
Stabilize the installation condition.
Adjust the installation distances to meet specified re-
quirements.
Take proper measurement to avoid interference.
Change the location of the devices.
Swap the location of the transmitter and receiver.
Adjust horizontal axis to avoid beam reflection, or adjust
unit distance from reflective surface.
Adjust vertical axis to avoid beam reflection, or adjust
unit distance from reflective surface.
Take proper measurements to avoid beam interference.
Photoelectric Detector
ISC-FPB1-W30DS
ISC-FPB1-W60DS
30 m (100 ft)
60 m (200 ft)
60 m (200 ft)
120 m (400 ft)
°C (77°F)
6 mA
10 mA
°C (77°F)
24 mA
DC10.5V - 28VDC
50 ms - 700ms (Selectable)
°
+/- 90
°
+/-5
Form C relay (DC30V, 0.1A)
Form B relay (DC30V, 0.1A)
°
°
° F - +131° F
-25
C - +55
C (-13
(96% or less RH)
-30
°
C - +60
°
C (-22
° F - 140° F
IP55
380 g (0.84 lbs)
77 x 177 x 83 mm (3 x 7 x 3.27 in)
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
F.01U.282.674 | 05 | 2014.10 | C
ISC-FPB1-W90DS
90 m (300 ft)
180 m (600 ft)
15 mA
(95% or less)

Advertisement

loading

This manual is also suitable for:

Photobeam isc-photobeam fpb1-w60dsPhotobeam isc-fpb1-w90ds