Page 1
High-Resolution, Day/Night, Wide-Dynamic, Autofocus All-In-One Dome Camera with 22x Optical / 16x Digital Zoom and Vandal-Resistant Housing CVAW1417-LP Configuration Manual Siemens AG...
Use only spare parts and accessories that have been approved by the manufacturer. 1.2.1 Transport Damage during transport Keep the packaging material for future transportation. Do not expose the device to mechanical vibrations or shocks. Siemens AG 04.2011...
Always disconnect the power cable and other cables from the main power supply before performing maintenance. Disconnect the device from the mains supply before cleaning it. Do not use liquid cleaners or sprays that contain alcohol, spirit or ammonia. Siemens AG 04.2011...
There is a risk of minor injuries or damage to property IMPORTANT Malfunctioning may result Meaning of the hazard symbols The nature of the hazard is indicated by icons. CAUTION Dangerous area! CAUTION Dangerous electrical voltage! Important information. Siemens AG 04.2011...
Directives and standards Directives and standards The product complies with the requirements of the following EU directives. The EU declaration of conformity is available from: Siemens AG Siemensallee 84 76181 Karlsruhe European Directive 2004/108/EC "Electromagnetic Compatibility" Compliance with the European Directive 2004/108/EC has been proven by testing...
Details for ordering Details for ordering Type Part no. Designation Weight CVAW1417-LP S54561-C37-A1 ¼-inch Fixdome VAN D/N WD AF 1.1 kg CVVA-JB01 S54561-C50-A1 Mounting base for dome camera 0.4 kg Package contents Camera Installation Manual Software and documentation on CD...
Freeze Digital slow shutter (DSS) Automatic white balance (AWB) Automatic gain control (AGC) On-screen menu (OSD) Negative/Positive switching (NEGA/POSI) E function (H/V flip, rotation) High resolution Motion detection and face detection Privacy masking Zoom preset Home preset Siemens AG 04.2011...
Torx screw Dome cover Eye for support wire Abb. 2 Dome part definition Mounting parts Abb. 3 Mounting parts Torx screw T-20, 4.5x45 mm Plastic anchor Ø 6 x 35 mm O-ring Torx wrench T-20 Hole cap Template Siemens AG 04.2011...
Camera C1...C10 RS485 Keyboard Video Keyboard Video RS232 SIMATRIX Monitor Monitor When using the camera in conjunction with a video matrix switcher (SIMATRIX SYS, 648, 164) or other telemetry equipment (different protocol), an interface converter CAC0103 is required. Siemens AG 04.2011...
If not, the dome camera could fall, causing injury. Drill the mounting holes for the dome base using the drilling template. Abb. 4 Drill jig Siemens AG 04.2011...
Page 16
Attach the dome cover to the dome base using the torx screws. Cover the screw heads with the plastic caps provided. Optional: The mounting base CVAA-JB01 is provided if the cable run on the surface needs to be made vandal-resistant. Abb. 6 Mounting base Siemens AG 04.2011...
Aut. switching between Grey Ext. input colour and B/W / Black/White Ext. output Alarm input Remote control Black Orange Control RS-232 connection, Pink PC configuration Light blue MD output Violet MD/FD off: 0 V, on: 3.3 V Siemens AG 04.2011...
The camera can be controlled remotely by an external device or control system, such as a control keyboard, using RS-485 half-duplex. Connect marked Rx+, Rx- to Tx+ and Tx- of the RS-485 control system. RS-485(+) Green RS-485(-) Blue Siemens AG 04.2011...
5 MHz 6 dB 6 dB 12 dB Condition on delivery 8.1.4 Alarm output The alarm output (motion detection result or face detection result or external signal fed in) is active high. Alarm output Violet Black Siemens AG 04.2011...
Press the FAR side to focus on distant objects. The focus keys are activated when AF mode is Off. NEAR Press the NEAR side to focus on near objects and the FAR side to focus on distant objects. SPOT VIDEO OUT Siemens AG 04.2011...
TOUR CONFIG Press ENTER to save the tour configuration (preset combination) HOME PRESET Home preset On/Off HOME WAIT Waiting time after which the camera returns to start position (HOME PRESET) Back to the next higher menu level Siemens AG 04.2011...
Since the colour rolling path differs depending on the fluorescent lamp used, it has to be adjusted individually. To do so, select the WB menu. After about 10 s, the adjust mode will be finished automatically. Back to the next higher menu level Siemens AG 04.2011...
BLC area: 1-9, activated only in manual BLC mode BLC LEVEL Back-light compensation level: LOW, MID, HIGH WDR MODE WDR (Wide Dynamic Range) function On/Off WDR LEVEL WDR level: 10 – 50 Back to the next higher menu level Siemens AG 04.2011...
Adjust the location of the mask area with boundary bottom and right COLOUR Mask colour: 1 – 8 MOSAIC Mosaic display On/Off MOSAIC TYPE Mosaic roughness setting: 1 – 4 Back to the next higher menu level Siemens AG 04.2011...
Digital flip function: vertical flip/horizontal flip / 180° rotation FREEZE Real or still mode HI-RES High-resolution mode: Low/Mid/High 2DNR 2D noise reduction level: Off/01 – 7 3DNR 3D noise reduction level: Off/01 – 31 Back to the next higher menu level Siemens AG 04.2011...
BAUD RATE PROTOCOL Operating protocol: COMMAND: for factory use only SIEMENS – B (Parity bit = Even) SIEMENS – S (Parity bit = Even) MOLYNX (Parity bit = Even) PELCO – D (Parity bit = None) PELCO – P (Parity bit = None)
Therefore, the following maintenance tasks should be performed on a three-monthly basis: Inspect all connection cables for deterioration or other damage. Clean all components with a soft, clean cloth. Check that all fixings are secure. Siemens AG 04.2011...
It is a precondition for reuse and recycling of used electrical and electronic equipment. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product. Siemens AG 04.2011...