9 Troubleshooting

9 Troubleshooting
PROBLEM
The LED of the CS does not
change to Green ON.
<KX-TDA0158 only>
The maximum number of
PS calls that the CS
supports cannot be made.
The LED of the CS stays
Red ON during normal
operation.
"CLEAR SCAN DATA" is
displayed on the PS's
screen after turning on the
PS.
Cannot register the PS.
60
Quick Installation Guide
PROBABLE CAUSE
The optional service card is
not working.
CS is not connected
properly.
CS is not set for normal
operation.
The status of the port that
the CS is connected to is
Out of Service.
<Only when connecting a
KX-TDA0158 CS to a
KX-TDA600/KX-TDE100/
KX-TDE200/KX-TDE600>
The Local Processor (LPR)
software of the
corresponding DHLC/DLC
card is not version 5.000 or
later.
Poor connection
CS malfunction
The PS cannot be used for
normal operation when
scan data is stored on the
PS.
Wrong Personal
Identification Number (PIN)
is registered to the PS.
SOLUTION
Install the card properly.
Make sure that the cable is connected
properly with correct pin assignments.
Also, make sure that the cable does not
make short circuits.
Switch all DIP switches off.
Change the port status from Out of
Service to In Service using the
Maintenance Console.
Upgrade the LPR software of the
DHLC/DLC card.
Make sure that a 4-pair cable is used
for connection.
Replace the CS.
Clear the scan data by following the
procedure described in "Clearing the
Stored Scan Data" in "5 Site Survey
Using the KX-TCA175/KX-TCA255/
KX-TCA256/KX-TCA275/KX-TCA355/
KX-TD7590".
Enter the PIN set to the PBX into the
PS.