3.23.2 Sequence instruction
Instruction
Classification
Symbol
L D
LDI
AND
Contacts
ANI
O R
ORI
ANB
ORB
Connectio
MPS
n
MRD
MPP
OUT
SET
RST
Outputs
PLS
PLF
SFT
Shift
SFTP
Symbol
MPS
MRD
MPP
SET
D
RST
D
PLS
D
PLF
D
SFT
D
SFTP
D
Processing
Logical operation start
(Operation start at N/O
contact)
Logical NOT operation start
(Operation start at N/C contact)
Logical product
(N/O contact series
connection)
Logical product NOT
(N/C contact series
connection)
Logical sum
(N/O contact parallel
connection)
Logical sum NOT
(N/C contact parallel
connection)
AND between logical blocks
(series connection between
blocks)
OR between logical blocks
(parallel connection between
blocks)
Stores the operation result.
Reads the operation result
stored in MPS.
Reads and resets the
operation result stored in
MPS.
Outputs device.
Sets device.
Resets device.
Produces a pulse lasting one
program scan time on the
leading edge of input signal.
Produces a pulse lasting one
program scan time on the
trailing edge of input signal.
1-bit device shift
Instructions List
Executi
on
Conditi
on
1
1
1
111
1
1
1
1
117
1
1
1
120
1
1
123
3
1
3
126
1
3
3
3
129
3
3
131
3
105