Bail Calibration - HP C2858A Service Manual

Drafting plotters
Hide thumbs Also See for C2858A:
Table of Contents

Advertisement

BAIL CALIBRATION

In this procedure, the 'up' position of the bail assembly is calibrated. A value is stored in the
EEROM when the procedure is completed.
Perform the bail calibration whenever the:
D
D
Bail Calibration is accessible through the "Service Tests" menu. To perform the bail
calibration, do the following:
1. Press Enter at the "Status" display.
2. Use the arrow buttons to scroll to the "Utilities" main menu. Press Enter.
3. Simultaneously press the Enter and the Up Arrow buttons to access the "Service
Test" submenu.
4. Scroll to the "Bail Calib" submenu. Press Enter.
5. The bail will raise.
6. Press the Up Arrow button. Each time the button is pressed, the bail will raise
up slightly.
7. Press the Up Arrow button until the bail makes a slight falling motion. This is the
correct 'up' position.
8. Press Enter to store the calibration value in EEROM.
Download Free Service Manual and Resetter Printer at http://printer1.blogspot.com
the EEROM is cleared or replaced
the bail falls during media loading
Adjustments/Calibrations
7-9