LG 32LC2D Service Manual page 16

Hide thumbs Also See for 32LC2D:
Table of Contents

Advertisement

2. No Power
(1) Symptom
Does't minute discharge at module.
No front LED.
(2) Check follow
Power cord connected?
Cable connecting the Line Filter
and Power Board connected?
Is Fuse(F101) on Power Board
good?
Is the Power Board connected to
7P of VSC Board?
When ST-BY 5V does not operate,
replace Power Board.
Yes
Yes
Yes
Yes
No
Plug in power cord.
No
Connect Cable.
No
Replace Fuse.
No
Connect Cable.
- 16 -