Key Processing (Setting the Manual Test Mode) :
KEY
TEST POINT
INITIAL
TEST MODE
TALK
TP204 TP209
OFF
TP201 TP209 TEST MODE OFF
1
TP201 TP208
2
TP201 TP207
3
TP201 TP206 EEPROM CHECK
4
TP201 TP205
5
TP202 TP207 RSSI LOW SET
6
TP202 TP205
7
TP202 TP208 LIGHT OFF/ON
8
TP202 TP209
9
TP202
TP203
0
TP203 TP209 FORCED HOLD IN
#
TP203
REDIAL/
TP204
PAUSE
FLASH
TP204
CHANNEL TP204
HOLD
TP203 TP208 HI-CUT ON/OFF
ERASE
TP203
PROGRAM/
TP204 TP205
VOLUME
• When receiving data, the set is put in the same state as the
intermittent reception state during normal wait.
• The channel is counted up each time the CH key is pressed. When
the channel reaches 29 ch (15 ch for CN1), then it returns to 1 ch.
• The JOG key may be used to change the channel.
• To clear all of the EEPROM, simultaneously press ERASE and
TALK keys.
• "Channel Setting", "SIGOUT Control" and "Power Control" can
be separately set.
RX
FUNCTION
TX
RF
G
g
RX
g
g
TX & RX
G
G
G
g
RX
G
G
TX & RX OFF
KEY CHECK
g/G
DATA TX
G
g
DATA RX
TP206
TP205
G
G
TP206
TP208
TP207
TP206
TP207
VOL HI/LO
g : ON, G : OFF
– 15 –
KEY
RX
Light MUTE
LCD
MIC
AF
LCD HICUT
Light
g
g
G
g
g
g
g
g
G
G
G
G
g
g
G
g
G
g
G
g
g
g
g
g
g
g
g
g
g
g/G
G
G
G
G
G
G
G
G
g
g
g
g
DATA
RSSI
VOL
OUT-
SENS
PUT
G
NORM
HI
G
G
G
G
G
G
G
LOW
g/G
G
G
HI
G
g
HI/LOW