2-4. PICTURE TUBE REMOVAL

2 A board
5
Neck assy
6
Deflection yoke
8
Four screws
(Tapping screw 5)
1 Anode cap
11
Two degaussing
coil holders
• REMOVAL OF ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
after removing the anode.
• REMOVING PROCEDURES
a
1
Turn up one side of the rubber cap in
the direction indicated by the arrow a.
• HOW TO HANDLE AN ANODE-CAP
1
Don't scratch the surface of anode-caps with shartp shaped mate-
rial!
2
Don't press the rubber hardly not to damege inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don't turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or damage the rubber.
9
Demagnetic coil
GND
GND
GND
7
Picture tube
b
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow b.
10 Two tension springs
CN502
CN501
CN505
GND
GND
GND
4 Bottom cover
(D board)
12
Two
degaussing
coil holders
Cushion
2-2
CPD-E100/E100E
3 Four screws
(+BVTP 4 x 16)
CN603
CN906
Anode Button
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in
the direction of the arrow c.