Econavi Function - Panasonic CZ-RTC4 Operating Instructions Manual

Hide thumbs Also See for CZ-RTC4:
Table of Contents

Advertisement

ECONAVI Function

This function is available by attaching an optional ECONAVI sensor.
The ECONAVI sensor detects human activity and conserves energy based on the
activity level.
Overview of the ECONAVI function
High activity
Low activity
No one in the room
* When the sensor
detects movements in
the room which have
been empty, it will
resume operation to
match with the activity
level.
Note
 Even when target temperature is changed through the ECONAVI function, the set
temperature shown in the remote controller does not change.
 Even when Cooling/Heating is changed to Fan through the ECONAVI function,
the operation mode shown in the remote controller will still be Cooling/Heating.
 It is possible to choose from the following options for the operation to be
performed after a lapse of 3 hours since the room has been empty.
• Operates in the Fan mode only.
• Stops and resumes operations after human movements are detected.
• Stops and will not resume operations even after human movements are detected.
• Continues to operate in the current mode.
If you need to do so, please contact the dealer.
22
(EN)
• Cooling: Target temperature is the same as the set temperature.
• Heating: Target temperature is 1 °C lower than the set
temperature.
• Cooling: Target temperature is 1 °C higher than the set
temperature.
• Heating: Target temperature is the same as the set temperature.
No one in the room for 20 minutes
• Cooling: Target temperature is 2 °C higher than the set
temperature.
• Heating: Target temperature is 2 °C lower than the set
temperature.
No one in the room for 3 hours
• Cooling: Cooling will stop and the unit will be in fan only mode.
• Heating: Heating will stop and the unit will be in fan only mode.