Figure 3-23. Timing Of Power-Up And Initialization Of Emmc - Motorola APX 5000 Service Manual

Hide thumbs Also See for APX 5000:
Table of Contents

Advertisement

Theory of Operation
: Controller
A GPIO named "MMC_RESET" will be used to soft-reset the eMMC card. This will be an output from
CPLD ball C7. This ball is on output high out of reset. On power-up software should drive the pin low
for at least 5ms and then drive it high. After reset is driven high, software needs to wait 250ms before
sending command CMD0 (argument = 0). Refer to the sw code to see how to add delays with
MMC_CLK running for at least 74 clock cycles after any reset occurs. If not, the eMMC will fail to
initialize and will not open since the OMAP does not run the clock continuously, so waiting 250ms
with no clock running will not configure eMMC correctly.
Supply voltage
V
CCQ,max
V
CCQ,min
Power-up time
V
CC,max
V
CC,min
the longest of 1ms, 74 clock cycles,

Figure 3-23. Timing of power-up and initialization of eMMC

Control logic
voltage range
Supply ramp-up time
Initialization sequence
CMD1
Initialization delay =
the supply ramp-up time,
or the boot operation period.
Memory field
working
voltage range
working
First CMD1 to card ready
N
N
CC
CC
CMD1
CMD1
Optional repetitions of CMD1
until the card is responding
with busy bit set
3-37
V
CCQ
N
CC
CMD2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apx 6000xeApx 6000Srx 2200

Table of Contents