management server. The buffer size for this field is 128 characters.
Site Contact: enter contact information relating to the module. This parameter will set the
supplied information into the sysContact SNMP MIB-II object and can be polled by a SNMP
management server. The buffer size for this field is 128 characters.
Site Location: enter information relating to the physical location of the module. This parameter
will set the supplied information into the sysLocation SNMP MIB-II object and can be polled by a
SNMP management server. The buffer size for this field is 128 characters.
Save Changes: by clicking on this button, any changes that have been made on the Configuration
page will be committed to flash memory and will take effect after the next module reboot.
Undo Save Changes: by clicking on this button, any changes that have been made and not
committed through a reboot of the module.
Set to Factory Defaults: depressing this button will change all of the configurable parameters (all
of which are contained on the Configuration page) back to their factory settings.
Reboot: depressing this button will reboot the module.
Canopy Default Plug
When inserted, the default plug brings the module up with a default configuration. This allows the
operator to regain control of a module, which may be using an IP address and/or password that
has been forgotten. The default plug will also override the passwords for access and change
control and set the LAN1 IP address back to 169.254.1.1. This does not, by itself, change any
configuration, rather, it allows the operator to attach to the module using the default configuration
so that they can read the actual non-default values and set them accordingly.
The following steps outline the creation of a default plug (this plug can also be purchase for a
nominal fee at
Obtain a RJ-11, 6-pin connector and a small length of CAT 5 cable.
Pin-out all 6-pins according the following diagram and then short (i.e. solder) together
pins 4 and 6 on the other end. Remaining wires should not be connected to anything.
The following diagram shows the wiring of a default plug:
pin 1 → white / orange
pin 2 → white / green
pin 3 → white / blue
pin 4 → green
pin 5 → blue
pin 6 → orange
Insert "default plug" in the GPS sync port of the module and apply power to the module
via its Ethernet cable.
When the module is booted up (power applied) it will be in default mode where the IP address will
be 169.254.1.1 and the passwords will be blank. All other configurations will have been preserved.
):
solder to orange
solder to green