Figure 16: Wiring The Dx2010 To The D6412/D4412; Figure 17: Wiring The Dx2010 For External Power Supply - Bosch D6412 Operation And Installation Manual

Hide thumbs Also See for D6412:
Table of Contents

Advertisement

If you need to power the DX2010 with an external 12 VDC power supply, wire it as shown in Figure 17. See Section 4.3
External Power Supply for external power supply restrictions.
© 2003 Bosch Security Systems
DX2010
+OUT-
TMPR
R
B
G

Figure 16: Wiring the DX2010 to the D6412/D4412

DX2010
+OUT-
TMPR
R
B
G
Red (+)
+
External 12 VDC
Power Supply

Figure 17: Wiring the DX2010 for External Power Supply

D6412/D4412 Operation and Installation Guide
Off-Board Sensors Loops
Y
1 COM
Green (Data)
Yellow (Data)
Black (-)
Red (+)
Y
1 COM
Green (Data)
Yellow (Data)
Black (-)
-
Page 35
D6412/D4412
D6412/D4412
R
Y
G
B
D6412/D4412
R
Y
G
B
45349E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D4412

Table of Contents