Sharp AH-A07BE Service Manual page 9

Split system room air conditioners
Hide thumbs Also See for AH-A07BE:
Table of Contents

Advertisement

INDOOR UNIT
OUTDOOR UNIT
TERMINAL BOARD 2
TERMINAL BOARD
1
BR
BR
1
BL
BL
G(Y)
G(Y)
TERMINAL BOARD 1
POWER SUPPLY
BK
: BLACK
W
: WHITE
BR
: BROWN
G(Y)
: GREEN-
R
: RED
YELLOW
BL
: BLUE
Figure W-4. Wiring Diagram for AU-A09BE
INDOOR UNIT
OUTDOOR UNIT
TERMINAL BOARD 2
TERMINAL BOARD
1
BR
BR
1
BL
BL
G ( Y )
G ( Y )
TERMINAL BOARD 1
POWER SUPPLY
: WHITE
W
: BLACK
BK
: GREEN-
G(Y)
: BROWN
BR
YELLOW
: RED
R
: BLUE
BL
Figure W-5. Wiring Diagram for AU-A09BE-C
INDOOR UNIT
OUTDOOR UNIT
TERMINAL BOARD 2
TERMINAL BOARD
1
1
BR
BR
1
BL
BL
G(Y)
G(Y)
TERMINAL BOARD 1
POWER SUPPLY
BK
: BLACK
W
: WHITE
BR
: BROWN
G(Y)
: GREEN-
R
: RED
YELLOW
BL
: BLUE
Figure W-6. Wiring Diagram for AU-A12BE
BL
BK
1
R
G(Y)
INTERNAL
CONTROL BOX
THERMAL
FUSE
FAN MOTOR
BK
BL
FAN MOTOR
BL
CAPACITOR
400(450)V 1.5µF
BL
BK
1
R
G ( Y )
INTERNAL
CONTROL BOX
THERMAL
FUSE
FAN MOTOR
BK
BL
FAN MOTOR
CAPACITOR
BL
400(450)V 1.5µF
BL
BK
R
G(Y)
INTERNAL
CONTROL BOX
THERMAL
FUSE
FAN MOTOR
BK
BL
FAN MOTOR
BL
CAPACITOR
400(450)V 2µF
9
COMPRESSOR MOTOR
MOTOR PROTECTOR
BK
C
R
S
W
R
RUNNING
CAPACITOR
400V 30µF
COMPRESSOR MOTOR
INTERNAL
MOTOR
C
PROTECTOR
S
R
W
R
RUNNING
CAPACITOR
400V 25µF
COMPRESSOR MOTOR
INTERNAL
MOTOR
C
PROTECTOR
R
S
W
R
RUNNING
CAPACITOR
400V 30µF
AH-A07BE-C/09BE-C
AH-A07BE/09BE/12BE
AY-A07BE-C/09BE-C
AY-A07BE/09BE/12BE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents