Kenwood KDC-MP5036U Service Manual page 12

Hide thumbs Also See for KDC-MP5036U:
Table of Contents

Advertisement

KDC- MP5036U/MP535U/W6537U/
W6537UY/X591
[1]
Key pressed briefl y: DC offset error detection display 1 (To
key
show such detection as the improper connection and other
detection)
Key pressed and held for 2 seconds: Clear the information
that indicated if there was such an error as improper
connection and other error.
(Display) DC1_ OK_ _ (No error was detected)
ERR_ (Improper connection or other error is
[2]
Key pressed briefl y: DC offset error detection display 2 (To
key
show the number of capacitor leaks.)
Key pressed and held for 2 seconds: Clear the information
that indicates the detected number of capacitor leaks.
(Display) DC2_ 0_ _ _ (No error was detected )
1
2
3
4
4. DC offset error display mode is cancelled by resetting. (The
last screen will not be retained.)
(Note) In this mode, the DC offset error detection display
"PROTECT" is not shown.
● FM/AM channel space switching (KDC-MP5036U/
MP535U/X591 only)
While power is OFF, press and hold [1] and [5] keys, and
press [SRC] key to power ON.
● Security
How to enter the forced POWER ON mode
While "_ _ _ _" is being displayed, while simultaneously
pressing [MENU] key and [4] key, press [RESET] button,
With this, it is possible to turn the power on for 30 minutes
only.
• How to register the security code on the "Car
Audio Passport" sheet after replacing E2PROM
(in the front-end: A500 of X34-) (KDC-MP5036U/
W6537U/W6537UY only)
1. Enter the test mode. (Refer to "How to enter the test
mode".)
12
TEST MODE
detected.)
(Leak was detected once.)
(Leak was detected 2 times.)
(Leak was detected 3 times.)
(Leak was detected 4 times or more.)
2. In the test mode, press [MENU] key briefl y to enter the
MENU mode.
When "CODE_SET" is displayed, press [
second or longer to enter the security registration mode.
3. Input the security code, using [FM] / [AM] / [
keys.
[FM] key : number up / [AM] key : number down
[
] key : cursor to right / [
4. After inputting the code, press [ ] key for 3 seconds or
longer which causes "RE-ENTER" to be displayed. This is
for "confi rming" the code. Use the method in the step 3 to
re-enter the code.
5. Then, press [ ] key for 3 seconds or longer, which will
display "APPROVED". This completes the security code
registration.
6. Release the test mode. (Refer to "How to clear the test
mode".)
* Note: All clear cannot be used to clear the security code.
• How to clear the programmable security code
(KDC-MP535U/X591 only)
1. While "_ _ _ _" is being displayed, press [
seconds or longer while pressing the [AUTO] or [TI] keys.
(This makes the "_ _ _ _" display disappear.)
2. Input "KCAR", using the remote controller.
Press [5] key of the remote controller 2 times (Input for "K")
and press [
] key.
Press [2] key of the remote controller 3 times (Input for "C")
and press [
] key.
Press [2] key of the remote controller once (Input for "A")
and press [
] key.
Press [7] key of the remote controller 2 times (Input for "R")
and press [
] key.
3. The security is cleared and the unit enters STANDBY
source.
4. If wrong codes are input, "_ _ _ _" will be displayed again.
] key for 1
] / [
]
] key : cursor to left
] key for 3