Model 3001KL-AM/3001KL-AMC
Antimicrobial Digital Platform Scale

User Instructions

P/N UM3001KL-AM Rev20160407
1

Advertisement

Table of Contents
loading

Summary of Contents for Health O Meter 3001KL-AM

  • Page 1: User Instructions

    Model 3001KL-AM/3001KL-AMC Antimicrobial Digital Platform Scale User Instructions P/N UM3001KL-AM Rev20160407...
  • Page 2: Table Of Contents

    Model 3001KL-AM/3001KL-AMC ® Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully, and keep it for easy reference or training. TABLE OF CONTENTS Caution and Warning....................3 Specifications for This Scale ..................4 Certifications / Connectivity / Disposal ..............
  • Page 3: Caution And Warning

    If applicable, operate this scale exclusively with the AC adapter provided by • ® Health o meter Professional. Use of an unspecified adapter will void the warranty, and can pose a serious safety hazard. Operating this scale at voltages and frequencies other than specified can •...
  • Page 4: Specifications For This Scale

    (KG), the scale can be “locked” such that the user cannot change the displayed Unit of Measurement (UOM). Note: The 3001KL-AM/3001KL-AMC scale is shipped from the factory locked in “KG” mode. Refer to Page 13 to learn more about configuring the scale.
  • Page 5: Certifications / Connectivity / Disposal

    USB port. This connectivity helps minimize transcriptions errors when recording patient data. This scale is EMR-EHR compatible. For more information regarding how to connect this ® scale to other electronic devices, please contact Health o meter Professional Scales Technical Support, available during normal business hours at 1-800-638-3722. Scale Disposal ®...
  • Page 6: Assembly Instructions 3001Kl-Am/3001Kl-Amc Scale

    4. Place batteries into the battery holder, located on the side of the display assembly (see “Replacing / Inserting Batteries” information below). 5. For the 3001KL-AM model only, connect the AC adapter into the adapter jack (the jack is located on the rear of the display assembly). Plug the scale’s AC adapter into the power source.
  • Page 7 CON’T. Warning: To avoid a safety hazard, do not use an unspecified AC adapter. Only ® use the Health o meter Professional AC adapter model ADPT30 designed for this scale. Note: Use of AC adapter not available on 3001KL-AMC model.
  • Page 8: Setup / Batteries

    3. Replace or install the (6) AA batteries with new units. Follow the correct orientation of battery placement. ® 4. Health o meter Professional recommends using an alkaline or lithium battery, rated for 130° F (54° C) operation. Do not use Zinc-Carbon batteries. Always replace all six batteries at the same time.
  • Page 9: Quick Start Instructions

    QUICK START / OPERATING INSTRUCTIONS Keypad Figure 4 Function Description ON/OFF Power scale on and off. ZERO Zeros the scale prior to a weighing. Holds the weight value of the patient on the display until the button is HOLD/RELEASE pressed again to clear the value. Also moves the cursor from left to right ►...
  • Page 10 QUICK START / OPERATING INSTRUCTIONS (CONT) Refer to Figure 4 for Button Locations Weighing a Patient 1. Make sure there is no object on the weighing platform. 2. Press the ON/OFF button to power the scale on. 3. Wait until the “0.0” LB or “0.0” KG appears on the display. 4.
  • Page 11 When using this scale, the weight of an object, such as a cane, can be subtracted from the total weight in order to determine the weight of the patient alone. The Tare Function automatically performs this subtraction. The 3001KL-AM/3001KL-AMC scales allow tare weight to be entered manually by using the keypad, or automatically, as outlined in this section.
  • Page 12 QUICK START / OPERATING INSTRUCTIONS (CONT) 3. Wait until the “0.0” LB or “0.0” KG and “ZERO” appear on the display. 4. Hold down the TARE button for 3 to 5 seconds. The word “TARE” will appear at the bottom center of the display, and the user will be prompted to enter the tare value. 5.
  • Page 13: Unit Of Measurement (Uom) Configuration

    QUICK START / OPERATING INSTRUCTIONS (CONT) 6. The scale will prompt you to enter the patient’s height. Use the keypad ▲ and ► buttons to enter the patient’s height. Note: When weighing in pounds, the height is displayed in inches. When weighing in kilograms, the height is displayed in centimeters.
  • Page 14: Maintenance

    Maintenance The following pages provide instructions for maintenance, cleaning, calibration, and troubleshooting for the 3001KL-AM/3001KL-AMC scale. Maintenance operations other than those described in this manual should be performed by qualified service personnel. Caution: Before first use, or after long periods of non-use, check the scale for proper operation and function.
  • Page 15: Calibration

    Calibration This scale has been factory calibrated, and does not require calibration prior to use. Calibration of your 3001KL-AM/3001KL-AMC scale can be performed using calibrated kilogram (kg) or pound (lb) weight standards. The required calibration standard will be the Unit of Measurement (UOM) for which the scale is configured.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Troubleshooting Before contacting service personnel, refer to the following instructions to check and to correct any failures. Symptom Possible Cause Corrective Action Scale does not power on 1. Dead Battery 1. Replace batteries 2. Faulty electrical outlet 2. Use a different outlet 3.
  • Page 17: Warranty

    ® Health o meter Professional products are manufactured, designed, and owned by Pelstar, LLC. ® We reserve the right to improve, enhance, or modify Health o meter Professional product features or specifications without notice. © Pelstar, LLC 2016 P/N UM3001KL-AM Rev20160407...