Hitachi RAC-10GH5 Service Manual
Hide thumbs Also See for RAC-10GH5:

Advertisement

RAC-10GH5
RAC-10 KH3
RAC-14GH5
RAC-1
4K
H3
TYPE
MODEL
POWER SOURCE
TOTAL INPUT
TOTAL AMPERES
COOLING
CAPACITY
TOTAL INPUT
TOTAL AMPERES
HEADING
CAPACITY
DIMENSIONS
(mm)
NET WEIGHT
(kg)
RAS-08AH1/RAC-08AH1
RAS-10AH1/RAC-10AH1
RAS-14AH1/RAC-14AH1
RAS-10GH5
RAS-14GH5
RAS-10 KH3
RAS-14 KH3
COOLING
UNIT
RAS-10GH5
RAS-10 KH3
780
(W)
3.58
(A)
(Kw)
2.50
8,530
(BTU/H)
770
(W)
(A)
3.54
2.80
(Kw)
9,554
(BTU/H)
W
780
280
H
D
210
9
HHAW
RAS-10GH5/RAC-10GH5
RAS-14GH5/RAC-14GH5
RAS-10KH3/RAC-10KH3
RAS-14KH3/RAC-14KH3
HOW TO USE
INS TRUCTION
WALL TYPE
CONDENSING
COOLING
UNIT
UNIT
RAC-10GH5
RAS-14GH5
RAC-10 KH3
RAS-14KH3
1 ,230V,50 HZ
700
780
505
280
258
210
30
NO.0043E
5
17
19
21
24
26
27
31
33
CONDENSING
UNIT
RAC-14GH5
RAC-14 KH3
1,090
5.00
3. 0
5
11,942
1,100
5.05
4.0
13,648
750
548
288
9
37

Advertisement

loading

Summary of Contents for Hitachi RAC-10GH5

  • Page 1 HHAW NO.0043E RAS-10GH5/RAC-10GH5 RAS-14GH5/RAC-14GH5 RAS-10KH3/RAC-10KH3 RAS-14KH3/RAC-14KH3 HOW TO USE INS TRUCTION RAC-10GH5 RAC-10 KH3 RAS-10GH5 RAS-14GH5 RAS-10 KH3 RAS-14 KH3 RAC-14GH5 RAC-1 WALL TYPE COOLING CONDENSING COOLING CONDENSING TYPE UNIT UNIT UNIT UNIT RAS-10GH5 RAC-10GH5 RAS-14GH5 RAC-14GH5 MODEL RAS-10 KH3...
  • Page 6: Specifications

    SPECIFICATIONS RAS-08AH1 RAC-08AH1 RAC-14AH1 RAS-14AH1 RAS-10AH1 RAC-10AH1 RAC-14GH5 RAS-14GH5 MODEL RAC-10GH5 RAS-10GH5 RAC-14KH3 RAS-14KH3 RAC-10KH3 RAS-10KH3 FAN MOTOR 28 W 11 W FAN MOTOR CAPACITOR FAN MOTOR PROTECTOR COMPRESSOR – ASL145SV-C7LU ASG108TV-A7AT COMPRESSOR MOTOR CAPACITOR OVERLOAD PROTECTOR OVERHEAT PROTECTOR FUSE (for MICROPROCESSOR) 3.15 A...
  • Page 7: Operation Indicator

    RAS-10G H5 RAS-14G H5 RAS-10K H3 RAS-14K H3 RAS-10G H5 RAS-14G H5 RAS-10K H3 RAS-14K H3 OPERATION INDICATOR The auto restart feature prompts the air-conditioner to restart in its previous setting right after the power failure. In case of the power failure during the use of timer mode (Sleep Timer or ON/OFF Timer), timer mode is cancelled and the air-conditioner stops operation.
  • Page 12 Adjustment of the conditioned air in the upward and downward directions. The horizontal air deflector is automatically set to the proper angle suitable for each operation. The deflector can be swung up and down continuously and also set to the desired angle using the “...
  • Page 13 When using the remote control,if there is no response from the air conditioner unit and / or the remote control has fading and dim displays,the batteries in the remote control device need to be removde and replaced with new ones...
  • Page 16: Air Filter

    CAUTION Cleaning and maintenance must be carried out when filter lamp lights. Before cleaning, stop operation and switch off the power supply. AIR FILTER Clean the Pre-filter, as it removes dust inside the room. In case the Pre-filter is full of dust, the air flow will decrease and the cooling capacity will be reduced.
  • Page 17: Cleaning Of Front Panel

    CLEANING OF FRONT PANEL Remove the front panel and wash with clean water. Wash it with a soft sponge. After using neutral detergent, wash thoroughly with clean water. When front panel is not removed, wipe it with a soft dry cloth. Wipe the remote controller thoroughly with a soft dry cloth.
  • Page 18 PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONAL EITHER EVERY HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT OR SERVICE SHOP. Is the earth line disconnected or broken? Is the mounting frame seriously affected by rust and is the outdoor unit tilted or unstable? Is the plug of power line firmly plugged into the socket? (Please ensure no loose contact between them).
  • Page 20 THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before installation.) WARNING WARNING • The unit should be mounted at stable, non-vibratory location • The Outdoor unit must be mounted at a location which can which can provide full support to the unit.
  • Page 21: Construction And Dimensional Diagram

    CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS-08AH1, RAS-10AH1, RAS-14AH1 RAS-10GH5, RAS-10KH3 RAS-14GH5, RAS-14KH3 INDOOR UNIT HITACHI...
  • Page 22: Outdoor Unit

    CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC-08AH1, RAC-10AH1 RAC-10GH5, RAC-10KH3 OUTDOOR UNIT...
  • Page 23 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC-14AH1 RAC-14GH5, RAC-14KH3 OUTDOOR UNIT Handle Handle Air outlet Air Suction grill Rear side Holes for anchor bolt (2 – ø12 x 6 slots for ø8.0 bolt) Notch for anchor bolt (for 2 – ø8.0 bolt) Fixing hole Drain hole Drain hole...
  • Page 24 RAS-10G H5 RAS-10G H5 RAS-10K H3 RAS-10K H3 RAS-14GH5 RAS-14GH5 RAS-14K H3 RAS-14K H3 14G H5 RAS-10GH5 RAS-14G H5 10GH5 14KH3 C-10K H3 RAS-10K H3 RAS-14 KH3 WM = 316 WM = 4 4 8 WM = 566 WA = 3 4 1 WA = 175 WA = 2 5 0 -19-...
  • Page 25 RAC-10G H5 RAC-14G H5 RAC-14K H3 RAC-10K H3 AGS/08TV-B7AT AGS/08TV-B7AT 220 - 240 220 - 240 3.72 2.45 3.60 2.92 -20-...
  • Page 26 RAS- 10GH5 /RAC-10GH5 RAS-14GH5/RAC-14GH5 RAS-10K H 3 /RA C-10 KH3 RAS-1 3/RA RAC-10G H5/RAC-10KH3 RAC-1 G H5/RAC-1 4KH3 -21-...
  • Page 27 -22-...
  • Page 30 RAS-10GH5 RAS-14GH5 RAS-10KH3 RAS-14KH3 -25-...
  • Page 31 -26-...
  • Page 32 -27-...
  • Page 33 -28-...
  • Page 34 -29-...
  • Page 35 -30-...
  • Page 36 RAS-10GH5/RAC-10GH5 RAS-10KH3/RAC-10KH3 -31-...
  • Page 37 RAS-14GH5/RAC-14GH5 RAS-14KH3/RAC-14KH3 9.52 9.52 9.52 9.52 -32-...
  • Page 38: Parts List And Diagram

    PARTS LIST AND DIAGRAM MODEL RAS-10GH5,RAS-14GH5,RAS-10K H3,RAS-14K H3 -33-...
  • Page 39 RAS-10GH5,RAS-14GH5 HHAW PARTS NO Q'TY/ PARTS NAME UNIT RAS-10GH5 RAS-14GH5 HWRAS-10GH5 HWRAS-08BH3 HWRAS-10GH5 HWRAS-10GH5 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 907 HWRAS-14BH4 901 STEPPING MOTOR HWRAS-10GH5 HWRAS-08BH5 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 915 HWRAS-10GH5 A02 FAN MOTOR SUPPORT HWRAS-10GH5 A03 HWRAS-14GH5 A01 EVAPORATOR ASS'Y HWRAS-10GH5 A04 HWRAS-14GH5 A02...
  • Page 40 RAS-10KH3,RAS-14KH3 HHAW PARTS NO Q'TY/ PARTS NAME UNIT RAS-10KH3 RAS-14KH3 HWRAS-10GH5 HWRAS-08BH3 HWRAS-10GH5 HWRAS-10GH5 HWRAS-10KH3 HWRAS-08BH3 HWRAS-08BH3 907 HWRAS-14BH4 901 STEPPING MOTOR HWRAS-10GH5 HWRAS-08BH5 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 HWRAS-08BH3 915 HWRAS-10GH5 A02 FAN MOTOR SUPPORT HWRAS-10GH5 A03 HWRAS-14GH5 A01 EVAPORATOR ASS'Y HWRAS-10GH5 A04 HWRAS-14GH5 A02...
  • Page 41 RAC-10GH5,RAC-10KH3 -36-...
  • Page 42 RAC-10GH5,RAC-10KH3 HHAW PARTS NO Q'TY PARTS NAME /UNIT RAC-10GH5 RAC-10KH3 RAC-MES09HX001 TOP COVER RAC-MES09HX002 CONDENSER HWRAC-10GH5A01 REVERSING VALVE HWRAC-10GH5A02 C-VALVE-AS HWRAC-10GH5A03 UNION(3) HWRAC-10GH5A04 UNION(2) HWRAC-10GH5A05 COMPRESSOR RAC-MES09HX008 SIDE COVER (L) HWRAC-10GH5A06 SIDE COVER (R) HWRAC-10GH5A07 BASE RAC-MES09HX011 TERMINAL COVER RAC-MES09HX012...
  • Page 43 RAC-14GH5,RAC-14KH3 -38-...
  • Page 44 RAC-10GH5,RAC-10KH3 HHAW PARTS NO Q'TY PARTS NAME /UNIT RAC-14GH5 RAC-14KH3 RAC-MES14HX001 TOP COVER HWRAC-14GH5A01 CONDENSER HWRAC-14GH5A02 REVERSING VALVE HWRAC-14GH5A03 ONEWAY-VALVE-AS HWRAC-14GH5A04 UNION(3) HWRAC-14GH5A05 UNION(2) HWRAC-14GH5A06 COMPRESSOR RAC-MES14HX008 SIDE COVER (L) RAC-MES14HX009 SIDE COVER (R) RAC-MES14HX010 BASE RAC-MES14HX011 SERVICE VALVE COVER...
  • Page 45 -40-...
  • Page 46 -41 -...
  • Page 47 RAS-10GH5/RAC-10GH5 RAS-14GH5/RAC-14GH5 RAS-10KH3/RAC-10KH3 RAS-14KH3/RAC-14KH3...