Diagnosis; Power On Sequence - Pioneer BDP-05FD Service Manual

Hide thumbs Also See for BDP-05FD:
Table of Contents

Advertisement

5

5. DIAGNOSIS

QQ
3 7 63 1515 0

5.1 POWER ON SEQUENCE

Power On Sequence
Pressing of the POWER key is detected by the IC4001 Submicrocomputer on the MAIN Assy.
The IC4001 then outputs a POWER_ON signal to the SYPS Assy.
After receiving the POWER_ON signal, the SYPS Assy activates, secondary
Power[SW+12 V], setting it to ON.
The R8A34019BG (IC1001), the core LSI, starts up. {RS-232C connectorCN1601,
log it to ON}
Communication between the R8A34019BG and the DDR2 SDRAM starts.
Communication between the R8A34019BG and the FLASH_IC starts.
TE
L 13942296513
It takes about 1 minute to complete the startup process.
Troubleshooting
Are the pins at CN7001 and CN7002 supplied with voltages?
MAIN ASSY(1/8) V+3S, V+3PLL with 3.3 voltages?
MAIN ASSY(1/8) V+1R8S with 1.8 voltages?
MAIN ASSY(1/8) V+1R1S with 1.1 voltages?
Is the reset signal H? (R1161)
Is the 27 MHz CLK oscillating? (R1141)
Power ON, and log of R8A34019BG stops with [DRAM failed].
R8A34019BG and communication failure of DDR memory.
www
Power ON, and log of R8A34019BG stops with [zboot failed].
R8A34019BG and communication failure of FLASH memory.
.
5
http://www.xiaoyu163.com
6
x
ao
u163
y
i
6
http://www.xiaoyu163.com
7
2 9
8
Q Q
3
6 7
1 3
1 5
co
.
BDP-05FD
7
8
9 4
2 8
0 5
8
2 9
9 4
2 8
m
8
9 9
A
B
C
9 9
D
E
F
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bdp-51fd

Table of Contents