parameters, such as Output Resolution. Visual feedback for the adjustments of Setup Mode is
seen on the 24 x 2 LCD display, rather than on OSM of the main screen. Sensitive parameters
are placed in the Setup Menu so that an inadvertent key stroke with the IR remote does not cause
a change in a parameter that would be difficult to recover from. Table 1 lists the Setup
parameters and Table 2 lists the output resolutions currently supported in the unit.
Parameter
OUT = XXX ## Hz
LCD Brightness = On (Off)
Output Sync = Free Run (Vadjust 1:1,
Vjam)
BAUD = #####
OSM Location = Input (Output)
PC Control = Active (Inactive)
DHCP = On (Off)
IP=aaa.bbb.ccc.ddd
DNS=aaa.bbb.ccc.ddd
nd
2
DNS=aaa.bbb.ccc.ddd
Gateway=aaa.bbb.ccc.ddd
SubMask=aaa.bbb.ccc.ddd
Serial No = ######
MAC = ## ## ## ## ## ##
1
The default parameters configurations are highlighted in bold.
NEC Solutions, Inc.
Table 1: Setup Parameters
1
Description
Cycles through all of the available TheaterSync output
Table 2
modes (see
Turns On (Off) the 24 x 2 LCD Display during Operate
Mode
These settings enables to adjust the output sync:
Free Run – Establishes a precise output timeline
Vadjust 1:1 – Forces the output timeline to be frame
locked to the input by inserting or deleting entire lines of
output video
Vjam – Maintains frame lock by truncating final line of
output frame
Lets you choose a baud rate of 1200, 9600, 19200,
57600, or 115000.
The OSM may be located pre (Input side) or post (Output
side) scaling and keystone correction
Turns On (Off) the computer control capability
Turns on Dynamic IP Address Selection
Select IP Address (selectable only if DHCP = Off)
Select DNS Address (selectable only if DHCP = Off)
Select Alternate DNS Address
(selectable only if DHCP = Off)
Select Gateway Address (selectable only if DHCP = Off)
Select SubNet Mask (selectable only if DHCP = Off)
Indicates the Serial # of TheaterSync unit
Indicates the MAC Address of TheaterSync unit
MKT-0026-UMN-1.002F
for a list of Output Resolutions).