Electrical Adjustments
Group/
Item Name
Item
0 Temp A Warning (High)
1 Temp B Warning (High)
 Temp C Warning (High)
3 Temp B-A Warning (High)
4 Temp C-A Warning (High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
1 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
15
(Temp)
16 Temp B Warning Offset
(Temp)
17 Temp C Warning Offset
(Temp)
18 Temp B-A Warning Offset
(Temp)
19 Temp C-A Warning Offset
(Temp)
Temp A Warning Offset
0
(Time)
Temp B Warning Offset
1
(Time)
 Temp C Warning Offset
(Time)
Temp B-A Warning Offset
3
(Time)
4 Temp C-A Warning Offset
(Time)
Group
Fan control range Setting (temp./Voltage)
254
0 High Fan Control Min Temp
1 High Fan Control Max Temp
 High Fan1 Min
3 High Fan1 Max
4 High Fan Min
5 High Fan Max
6 High Fan3 Min
7 High Fan3 Max
8 High Fan4 Min(LAMP1)
9 High Fan4 Max(LAMP1)
10 High Fan5 Min(LAMP1)
11 High Fan4 Max(LAMP1)
1 Normal Fan Control Min Temp
13 Normal Fan Control Max
Temp
14 Normal Fan1 Min
15 Normal Fan1 Max
16 Normal Fan Min
17 Normal Fan Max
18 Normal Fan3 Min
19 Normal Fan3 Max
0 Normal Fan4 Min
1 Normal Fan4 Max
 Normal Fan5 Min
Function
Temp. A to judge the Temp Error at
High (Room)
Temp. B to judge the Temp Error at
High (Panel)
Temp. C to judge the Temp Error at
High (Lamp)
Temp. B-A to judge the Temp Error at
High (Clogging Det.)
Temp. C-A to judge the Temp Error at
High (Clogging Det.)
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco (Panel)
Temp. C to judge the Temp Error at
Eco (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Senser Control Start/End Temp.
at High
Fan voltage value at High (unit: 0.1V)
Temp Senser Control Start/End Tem.p
at Normal
Fan voltage value at Normal (unit:
0.1V)
Initial
51
51
64
64
59
59
100
100
100
100
44
44
60
60
60
60
100
100
100
100
44
44
60
60
60
60
100
100
100
100
5
15
15
100
100
15
30
30
40
40
Normal
Ceiling
9
9
38
38
100
100
135
135
85
85
130
130
75
80
80
85
-
-
-
-
-
-
-
-
33
33
38
39
7
77
15
15
68
75
80
80
77
8
135
135
-
-
-
-
-
-
-45-
range
Note
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents