Electrical Adjustments
Group/
Item Name
Item
3 Normal Fan5 Max
4 Eco Fan Control Min Temp
5 Eco Fan Control Max Temp
6 Eco Fan1 Min
7 Eco Fan1 Max
8 Eco Fan Min
9 Eco Fan Max
30 Eco Fan3 Min
31 Eco Fan3 Max
3 Eco Fan4 Min(LAMP1)
33 Eco Fan4 Max(LAMP1)
34 Eco Fan5 Min(LAMP1)
35 Eco Fan5 Max(LAMP1)
Group
Fan Start/cooling Setting
255
0 Fan1 Initial Volt
1 Fan Initial Volt
 Fan3 Initial Volt
3 Fan4 Initial Volt
4 Fan5 Initial Volt
5 Fan6-8 Initial Duty
6 Fan8 Initial Volt
8 Cooling Time L1
9 Cooling Time L
10 Temp Error Cooling Time
11 OnStart Cooling Start Thresh-
old
1 After shutdown cooling
Group
Fan lamp Voltage down Setting
256
0 Lamp Voltage
1 Lamp Vol Threshold
 Fan1 Speed Gain
3 Fan Speed Gain
4 Fan3 Speed Gain
5 Fan4 Speed Gain
Group
Fan dimmer Setting
257
Dimmer Average Check
0
Period
1 Dimmer Average
 Last Voltage Difference
3 Voltate Difference Goal
Group
Fan Ic temp for Netowrk model
258
Standby
Cooling
Check
0
Cycle
Standby
Cooling
Start
1
Threshold
 Standby Cooling Enable
Group
Fan Press Setting
259
0 Press Ssource Range Low
1 Press Ssource Range High
 Press Fan Add Range
High(Lamp In)
3 Press Fan Add Range
Low(Lamp In)
4 Press Fan Add Range
High(No Lamp In)
Press Fan Add Range Low
5
(No Lamp In)
Function
Temp Senser Control Start/End Tem.p
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time stting at Fan Mode L (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x
30 sec)
Cooling after shutdown (0: No, 1: Yes)
Current Lamp Voltage (0.1V)(Read
only)
Threshold to judge Lamp Voltage
Down ( V×10)
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, :6sec,
90sec...10:300sec)
Dimmer Avarage Value (Read only)
Temp A check cycle at Standby
Cooling start threshold temp A
Cooling in standby Enable
Initial
-
-
33
33
38
39
7
77
15
15
68
75
80
80
77
8
135
135
-
-
-
-
-
-
-
-
60
60
60
-
-
-
-
3
4
3
60
1
-
30
0
300
300
300
1
-
-
5
46
1
-
-
-
-
-
-
-46-
range
Note
0-55
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-145
0-145
0-145
0-55
0-55
0-55
0-55
1-15
1-15
1-15
0-100
0-1
0-55
30-90
0-55
0-55
0-55
0-55
0-10
-
-
0-100
0-100
0-1
0-103
0-103
0-5000
0-5000
0-5000
05000

Hide quick links: