Switching the 75-ohm Terminate Connectors

Removing the A Board
24
(EN)
Connections
Depending on the connections of the computer and color monitor to the
projector, it may be necessary to switch the 75-ohm terminate connectors
on the A board at the rear of the projector.
1
Loosen the two screws at the rear of the projector to remove the
connector panel.
2
Switch the CN1004, CN1005 and CN1006 on the A board.
For details, see "Setting the CN1006 (R), CN1005 (G) and CN1004 (B)
75-ohm terminate connectors."
3
Replace the A board by reversing step 1.
A board