Measurements - Nokia DNT2Mi sp/mp Operating Instructions Manual

Sp/mp data network terminal single-port and multiport
Table of Contents

Advertisement

6.8

Measurements

DN01145897
Issue 2-0 en
After all the settings have been checked, we recommend that you carry out a line
quality and a BER test.
Note
Before starting the BER test, reset all statistics and error counters. Read statistics
and error counters after the BER test.
Noise margins, Rx and Tx line levels, and attenuations (Q1: 7,1...3)
Establish a link between two units. After the line is up, check the noise margin,
Rx level, and line attenuation from the Measurements menu.
You can use Table 28 in Appendix A to mark down the results for line
attenuation.
Bit error rate test
We recommend you to perform a five-minute bit error rate (BER) test. For the
test, you need an external test equipment.
You can use Table 27 in Appendix A to mark down the results.
After the tests
Check that all alarms have disappeared and the statistics are still correct.
Table 3.
Monitoring a line
Tx level
Line 1 or 2: xx dBm
Rx level
Line 1 or 2: xx dBm
Noise margin
Line 1 or 2: xx dB
Attenuation
Line 1 or 2: xx dB
© Nokia Corporation
Nokia Proprietary and Confidential
xx = +7.5 to +14.5 dBm
xx = +14.5 to -26 dBm
xx = 0 to +15 dB
xx = 0 to 41 dB
Commissioning DNT2Mi
43 (128)

Hide quick links: