Kenwood TK-290 Service Manual page 42

Vhf fm transceiver
Hide thumbs Also See for TK-290:
Table of Contents

Advertisement

TK-290
Item
Condition
8. Maximum
1) Set panel test mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(Wide)
Select MDV
in panel tuning mode
Push Orange to 3 point
adjustment mode
Select MDV
L
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
2) Push Side2 to select
∗ ∗ ∗
POW
M
PTT : ON
3) Push Side2 to select
∗ ∗ ∗
POW
H
PTT : ON
9. Maximum
1) Set panel test mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
Select MDV
in panel tuning mode
Turn the toggle SW to the
right (narrow).
Push Orange to 3 point
adjustment mode
Select MDV
N L
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
2) Push Side2 to select
∗ ∗ ∗
POW
N M
PTT : ON
3) Push Side2 to select
∗ ∗ ∗
POW
N H
PTT : ON
10. MIC
1) Set panel test mode
sensitivity
CH No. : 3
check
Signalling No. : 1
AG : 1kHz/15mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
2) Turn the toggle SW to the
right (narrow)
PTT : ON
42
Measurement
Test-
Unit
equipment
Power meter Panel
Deviation
meter
∗ ∗ ∗
Oscilloscope
AG
Side
AF VTVM
∗ ∗ ∗
∗ ∗ ∗
∗ ∗ ∗
Adjustment
Terminal
Unit
Parts
ANT
Panel
Top1/
3.95kHz
Top2
(According to the
larger +, –)
Universal
1.90kHz
(According to the
larger +, –)
Check
Specifications/Remarks
Method
±50Hz
±50Hz
1.8kHz~3.6kHz
0.9kHz~1.8kHz

Hide quick links: