Kenwood TK-290 Service Manual page 46

Vhf fm transceiver
Hide thumbs Also See for TK-290:
Table of Contents

Advertisement

TK-290
Item
Condition
4. Sensitivity
1) Set panel test mode
adjustment
CH No. : 3
and check
Signalling No. : 1
(wide)
Select SNS
in panel tuning mode
Push Orange to 3 point
adjustment mode
Select SNS
L
SSG freq. : Low
output : –116dBm/0.35µV
2) Push Side2 to select
∗ ∗ ∗
SNS
M
SSG freq. : Center
3) Push Side2 to select
∗ ∗ ∗
SNS
H
SSG freq. : Hi
5. Sensitivity
1) Set panel test mode
check
CH No. : 1
(narrow)
Signalling No. : 1
SSG output : –116dBm/0.35µV
MOD. : 1kHz
DEV. : 1.5kHz
Turn the toggle SW to the
right (narrow)
2) Set panel test mode
CH No. : 3
Signalling No. : 1
Turn the toggle SW to the
right (narrow)
3) Set panel test mode
CH No. : 5
Signalling No. : 1
Turn the toggle SW to the
right (narrow)
6. Tight
1) Set panel test mode
squelch
CH No. : 3
adjustment
Signalling No. : 1
(wide)
Select SQ T
in panel tuning mode
7. Tight
1) Set panel test mode
squelch
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
Select SQ T
in panel tuning mode
Turn the toggle SW to the
right (narrow)
8. Squelch
1) Set panel test mode
adjustment
CH No. : 3
(wide)
Signalling No. : 1
Select SQ O
in panel tuning mode
SSG output : 3dB below to
12dB SINAD level
46
Measurement
Test-
Unit
equipment
SSG
Panel
AF VTVM Side
∗ ∗ ∗
Oscilloscope
Distortion
meter
Audio
∗ ∗ ∗
analyzer
∗ ∗ ∗
∗ ∗ ∗
∗ ∗ ∗φ
Adjustment
Terminal
Unit
Parts
ANT
Panel
Top1/
Adjust for maximum 12dB SINAD or more
Top2
SINAD
Universal
Check
Panel
Top1/
Normally set to 110
Top2
Adjust to point of
opening squelch
Specifications/Remarks
Method
12dB SINAD or more