Table of Contents

Advertisement

IP LDK-20 Installation Manual
ISSUE
DATE
ISSUE 1.0
2005.3
ISSUE 1.1
2005.6

Revision History

CONTENTS OF CHANGES
Initial Release
Add Expansion Modules and VMIBE/AAFBE
REMARK
Field test

Advertisement

Table of Contents
loading

Summary of Contents for LG IP LDK-20

  • Page 1: Revision History

    IP LDK-20 Installation Manual Revision History ISSUE DATE CONTENTS OF CHANGES REMARK ISSUE 1.0 2005.3 Initial Release ISSUE 1.1 2005.6 Add Expansion Modules and VMIBE/AAFBE Field test...
  • Page 2: Table Of Contents

    ■ PRECAUTION ....................2 ■ THE STRUCTURE OF MANUAL ..............3 SECTION 1. INTRODUCTION................4 1.1 The IP LDK-20 System highlights ..................4 1.2 System Connection Diagram ..................4 1.3 System Components ......................5 1.4 Specifications .........................6 1.4.1 General specifications......................6 1.4.2 System Capacity........................7 SECTION 2.
  • Page 3 5.4.3 External Paging wiring ..................... 63 5.4.4 Alarm Detection wiring ..................... 63 SECTION 6. STARTING THE IPLDK-20 SYSTEM ..........64 6.1 Before Starting the IP LDK-20 System ................64 6.2 Basic Preprogramming ....................64 6.2.1 DKTU (Station 10) programming..................64 6.2.2 Entering programming mode.................... 66 6.2.3 Pre-programming......................
  • Page 4: Important Safety Instructions

    IP LDK-20 Installation Manual Introduction ■ Important Safety Instructions Safety requirements When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and other personal injury, including the following: • Please read and understand all instructions.
  • Page 5: Precaution

    Precaution • Keep the system away from heating appliances and electrical noise generating devices such as fluorescent lamps, motors and televisions. These noise sources can interfere with the performance of the IP LDK-20 System. • This system should be kept free of dust, moisture, high temperature (more than 40 degrees) and vibration, and should not be exposed to direct sunlight.
  • Page 6: The Structure Of Manual

    ■ The Structure of Manual This installation manual is designed to provide as general information for the IP LDK-20 System. It provides instructions for installing the hardware, and programming the IP LDK-20 System using keyset. This manual contains the following sections: Section 1.
  • Page 7: Section 1. Introduction

    IP LDK-20 Installation Manual Introduction SECTION 1. INTRODUCTION 1.1 The IP LDK-20 System highlights Features of the IP LDK-20 System include: • Flexible architecture • Optional LAN Interface • Stable & enhanced voice features • Simple installation & efficient system management...
  • Page 8: System Components

    IP LDK-20 Installation Manual Introduction 1.3 System Components ITEM OPTION BOARD DESCRIPTION Key Service Unit Power Supply Unit, 90W MBUB Main Board Unit (2BRI, 4DKT, 2DKT/SLT, and 2SLT) Main CO boards Central Office Line interface boards (LCOB, STIB, CBIB) Board...
  • Page 9: Specifications

    IP LDK-20 Installation Manual Introduction 1.4 Specifications 1.4.1 General specifications ITEM DESCRIPTION SPECIFICATION AC Voltage Input 230 +/-10% Volt AC @47-63Hz AC Power AC Input Fuse 1.25A @ 250Volt AC DC Output Voltage +5, -5, +30Volt DC AC Adaptor AC Voltage Input 230 +/-10% Volt AC @47-63Hz for Expansion Module.
  • Page 10: System Capacity

    IP LDK-20 Installation Manual Introduction 1.4.2 System Capacity DESCRIPTION CAPACITY/BOARD TOTAL Time Slots 4/MBUB(BRI) Max. 16 CO Line Ports 4/LCOB or 4/STIB (Analog CO, ISDN BRI and/or IP trunk) 8/VOIM 8/MBUB Max direct Station connections 8/DTIB or 8/SLIB Max. 24...
  • Page 11: Section 2. Ksu Installation

    • Avoid using the same power supply outlet for computers, fax machines, and other office equipment to avoid induction noise interruption when using the IP LDK-20 near other machines. • The power and battery switches of the IP LDK-20 System must be OFF during wiring. After the wiring is completed, the power switch may be turned ON.
  • Page 12: Ksu Installation

    IP LDK-20 Installation Manual KSU Installation 2.2 KSU Installation 2.2.1 Unpacking Open the box and verify the items shown in Figure 2.2.1 are included: Mounting template Manual Key service unit Power cord Battery cable Tie cable Anchor plug Fuse Screw...
  • Page 13: Ksu Exterior And Dimension

    IP LDK-20 Installation Manual KSU Installation 2.2.2 KSU exterior and dimension Figure 2.2.2 shows the exterior and dimensions of the KSU: Figure 2.2.2 KSU exterior and dimension...
  • Page 14: Ksu With Expansion Module Exterior And Dimension

    IP LDK-20 Installation Manual KSU Installation 2.2.3 KSU with expansion module exterior and dimension Figure 2.2.3 shows the exterior and dimensions of the KSU: Figure 2.2.3 KSU with expansion module exterior and dimension...
  • Page 15: Opening And Closing The

    IP LDK-20 Installation Manual KSU Installation 2.2.4 Opening and closing the front cover 2.2.4.1 Opening the front cover 1. Turn the screw counter-clockwise to loosen as shown in Figure 2.2.4.1. 2. Lift the front cover in the direction of the arrow as shown:...
  • Page 16 Then put the front cover down on the KSU in the direction of the arrow, as shown. Turn the screws clockwise to tighten, as in the Figure. Figure 2.2.4.2 Closing the front cover • NOTE For safety reasons, close the front cover and tighten the screws prior to operating the IP LDK-20 System.
  • Page 17: Frame Ground Connection

    UL 1015 AWG# 18 (1.0mm). It is recommended that the ground wire be shorter than 1 meter (3.28 feet). • Proper grounding is very important to protect the IP LDK-20 system from external noise or to reduce the risk of electrocution in the event of lightning strike.
  • Page 18: Power Supply Unit (Psu) Installation

    IP LDK-20 Installation Manual KSU Installation 2.2.6 Power Supply Unit (PSU) installation The PSU has been installed in the KSU as a default when shipped. Before installation, make sure that the KSU not plugged into an outlet. The PSU is located at the left-most area of the KSU, and is capable of providing three kinds of power sources to MBUB through the 7PIN connector, CN19 (refer to the following table).
  • Page 19: External Backup Batteries Installation

    • Note : The cable for connecting the battery is supplied with the KSU. Operation of the batteries is controlled by the MBUB. This IP LDK-20 MBUB will provide charging current to the batteries during normal AC power operation at a maximum of about 100mA. During battery operation, the battery operation of MBUB will be stopped if the AC power re-applied or the battery voltage is too low to maintain full-system operation.
  • Page 20: Ksu Mounting

    IP LDK-20 Installation Manual KSU Installation 2.2.8 KSU mounting 2.2.8.1 Wall mounting 1. Install 3 anchor plugs in the wall using the mounting template included for accurate placement (Figure 2.2.8.1a). 2. Attach the mounting template with the included 3 screws.
  • Page 21 IP LDK-20 Installation Manual KSU Installation Figure 2.2.8.1b KSU Wall Mounting • Note : Be careful not to drop the KSU.
  • Page 22 IP LDK-20 Installation Manual KSU Installation 2.2.8.2 Rack mounting 1. Attach the rack bracket to the bottom of the IP LDK-20 system as shown in Figure 2.2.8.2a, and attach it to the system securely by tightening the screws clockwise. Figure 2.2.8.2a Rack Bracket 2.
  • Page 23: Section 3. Board Installation

    IP LDK-20 Installation Manual Board Installation SECTION 3. BOARD INSTALLATION 3.1 Installation of the Boards Prior to Board Installation, the following should be considered: CAUTION • Power must be turned OFF. • To protect the system from static electricity, do not touch the boards. To discharge static, touch a grounded object, or wear a grounding strap.
  • Page 24: Mbub (Main Board Unit)

    IP LDK-20 Installation Manual Board Installation 3.2 MBUB (Main Board Unit) Description The MBUB controls communication between the peripheral interfaces, supervises all resources in the system, controls the gain adjustment of the PCM signal, generates the system tones, and manages system call processing.
  • Page 25 IP LDK-20 Installation Manual Board Installation Figure 3.2b Connection The MBUB is installed in the KSU and provides various kinds of connectors and RJ45 modular jacks for the connection of peripheral boards and miscellaneous functions (refer to the following Table).
  • Page 26: Modular Jack(Mj1~Mj3) Pin Assignment

    IP LDK-20 Installation Manual Board Installation 3.2.1 Modular Jack(MJ1~MJ3) Pin Assignment 3.2.1.1 MBUB MJ1(CO) T Mode CONNECTOR PIN NUMBER SIGNAL NAME FUNCTION RJ45 1,2,7,8 Reserved Transmit Data Receive Data Receive Data Transmit Data NT1(NT - B OX) BRI Port1 T Interface...
  • Page 27 IP LDK-20 Installation Manual Board Installation S Mode CONNECTOR PIN NUMBER SIGNAL NAME FUNCTION RJ45 1,2,7,8 Reserved Receive Data Transmit Data Transmit Data Receive Data ISDN terminal TE1(or TA) BRI Port1 Only S interface 1 2 3 4 RJ45 type jack Max.
  • Page 28 IP LDK-20 Installation Manual Board Installation 3.2.1.2 MBUB MJ2 & MJ3(Extension) MBUB MJ2 CONNECTOR PIN NUMBER SIGNAL NAME RJ45 1,2,3 Reserved DKT-R, DKT-T 6,7,8 Reserved MBUB MJ3-1, 2 CONNECTOR PIN NUMBER SIGNAL NAME RJ45 DKT-R, DKT-T Reserved SLT-R, SLT-T 6,7,8...
  • Page 29 IP LDK-20 Installation Manual Board Installation 3.2.1.3 MJ4 Pin Assignment MBUB CONNECTOR PIN NUMBER SIGNAL NAME RJ45 Relay1-R, Relay1-T Relay2-R, Relay2-T EXT_PAGE-R, EXT_PAGE-T Alarm-R, Alarm-T 3.2.1.4 SW3 Functions and LED Indications SWITCH FUNCTION ON(DEFAULT) Administration Programming Access Disable Enable Command/Event Trace (The purpose of testing software)
  • Page 30 IP LDK-20 Installation Manual Board Installation 3.2.1.5 CN22 Pin assignment MBUB CONNECTOR PIN NUMBER SIGNAL NAME FUNCTION RS-232C Reserved Transmitted Data Received Data Not used Signal Ground Not used Not used Not used Reserved CONNECTOR PIN NUMBER SIGNAL NAME FUNCTION...
  • Page 31: Installation Of The Co Line Board

    IP LDK-20 Installation Manual Board Installation 3.3 Installation of the CO Line Board CONNECTOR BOARD PORT DESCRIPTION CABLE REMARK TYPE 2 ports LCOB RJ45 Loop Start CO Line Interface 2 wire (4 LCO) 2 ports Switched STIB RJ45 ISDN Basic Rate Interface (2B+D)
  • Page 32 IP LDK-20 Installation Manual Board Installation 3.3.1.1 Pin Assignment LCOB CONNECTOR PIN NUMBER SIGNAL NAME RJ45 CO1-R, CO1-T Reserved CO2-R, CO2-T 6,7,8 Reserved CONNECTOR FUNCTIONS CONNECTOR FUNCTION REMARK CN2 and CN3 PRCPTU4 or PRU4 connection CN1, CN2 and CN3 CPCU4 connection RJ45 type CO line connection 3.3.1.2 Add-On Boards...
  • Page 33 IP LDK-20 Installation Manual Board Installation PRCPTU4 (PR and CPT detection Unit) Description The PRCPTU4 can be optionally mounted on LCOB, and provides 4 channels of polarity reversal detection for call metering and call progress tone detection to support ACNR feature (Automatic Called Number Redial).
  • Page 34: Stib (Basic Rate Interface Board: Selectable S/T Interface)

    IP LDK-20 Installation Manual Board Installation 3.3.2 STIB (Basic Rate Interface Board: Selectable S/T interface) Description STIB should be installed on the LCOB/STIB/CBIB connector, and supports ISDN Basic Rate T-interface or S-interface. The 1st BRI port can be operated to T-mode or S-mode and the 2nd port can only be set to T-mode.
  • Page 35 IP LDK-20 Installation Manual Board Installation 3.3.2.1 Pin assignment T MODE CONNECTOR PIN NUMBER SIGNAL NAME FUNCTION RJ45 Reserved Transmit Data Receive Data Receive Data Transmit Data Reserved NT1(NT - BOX) STIB Port1 T Interface From/to PX 1 2 3 4 RJ45 type jack Max.
  • Page 36 IP LDK-20 Installation Manual Board Installation S MODE CONNECTOR PIN NUMBER SIGNAL NAME FUNCTION RJ45 Reserved Receive Data Transmit Data Transmit Data Receive Data Reserved ISDN terminal TE1(or TA) STIB Port1 Only S Interface RX - TX - 1 2 3 4...
  • Page 37 IP LDK-20 Installation Manual Board Installation 3.3.2.2 Line Connector and Terminating Resistors SW 1 AND SW4’S 1, 2 PIN SETTING : DEFAULT = ALL ON POSITION TERMINATING RESISTORS LINE NO RJ45 TYPE JACK REMARK SWITCH PIN1, 2 ON PIN1, 2 OFF...
  • Page 38: Cbib (Cid Loop Start Co Line + Basic Rate Interface Board)

    IP LDK-20 Installation Manual Board Installation 3.3.3 CBIB (CID Loop Start CO line + Basic Rate Interface Board) Description The CBIB can be installed on the LCOB/STIB/CBIB connector, and provides 2 CO/PBX Loop Start CO Line interfaces that support pulse/DTMF signal and one port of ISDN Basic Rate Interface T-mode. CO Interface circuit contains ring and loop current detection circuits, A/D and D/A conversions, and pulse signaling circuit.
  • Page 39 IP LDK-20 Installation Manual Board Installation 3.3.3.1 Pin Assignment CBIB 1’ST PORT FOR BRI T-MODE CONNECTOR PIN NUMBER SIGNAL NAME FUNCTION RJ45 Reserved Transmit Data Receive Data Receive Data Transmit Data Reserved CBIB 2’ND PORT FOR LCO CONNECTOR PIN NUMBER...
  • Page 40 IP LDK-20 Installation Manual Board Installation 3.3.3.2 Add-On Boards PRU2 (Polarity Reversal detection Unit) Description The PRU2 can be optionally mounted on CBIB, and provides 2 channels of Polarity Reversal detection for call metering. It also provides four on-hook connection paths for SMS.
  • Page 41: Installation Of The Extension Board

    IP LDK-20 Installation Manual Board Installation 3.4 Installation of the Extension Board BOARD PORT CONNECTOR TYPE REMARK DTIB4 4 DKT ports RJ45 Digital Terminal Interface : 4 ports DTIB8 8 DKT ports RJ45 Digital Terminal Interface : 8 ports SLIB4...
  • Page 42: Dtib8 (Digital Terminal Interface Board)

    IP LDK-20 Installation Manual Board Installation 3.4.2 DTIB8 (Digital Terminal Interface Board) Description DTIB8 can be installed on the SLIB/DTIB connector, and provides 8 Digital Keyset ports that are used for 2-wire connections to Digital Keysets. It has module connectors, MJ1 and MJ2, that are used to connect Digital Keyset lines to the DTIB8 and a din connector, CN2, to connect expansion modules like VOIM, SLIM, and DTIM.
  • Page 43: Slib4 (Single Line Interface Board)

    IP LDK-20 Installation Manual Board Installation 3.4.3 SLIB4 (Single Line Interface Board) Description SLIB4 can be installed on the SLIB/DTIB connector, and provides 4 SLT ports, and 2 DTMF receivers. The SLIB4 and SLT are connected with a RJ45 Modular Jack, MJ3 and SLIB4 has a din connector, CN3, to connect expansion modules like VOIM, SLIM, and DTIM.
  • Page 44: Slib8 (Single Line Interface Board)

    IP LDK-20 Installation Manual Board Installation 3.4.4 SLIB8 (Single Line Interface Board) Description SLIB8 can be installed the SLIB/DTIB connector, and provides the 8 SLT ports and 2 DTMF receivers. The SLIB8 and SLT are connected with a RJ45 Modular Jack, MJ2 & MJ3 and SLIB8 has a din connector, CN3, to connect expansion modules like VOIM, SLIM, and DTIM.
  • Page 45: Other Board Installations

    IP LDK-20 Installation Manual Board Installation 3.5 Other Board Installations 3.5.1 VMIB(Voice Mail Interface Board) Description The VMIB can be installed on the VMIB/AAFB connector, and provides system announcement, ACD/UCD announcement, and User Greeting. Figure 3.5.1 VMIB ITEM RECORD/PLAY Channel...
  • Page 46: Aafb(Auto Attendant Function Board)

    IP LDK-20 Installation Manual Board Installation 3.5.2 AAFB(Auto Attendant Function Board) Description The AAFB can be installed on the VMIB/AAFB connector, and provides system announcement and ACD/UCD announcement. Figure 3.5.2 AAFB ITEM RECORD/PLAY Channel 2 channels Max record time: 28 Min...
  • Page 47: Vmibe (Voice Mail Interface Board Enhanced)

    IP LDK-20 Installation Manual Board Installation 3.5.3 VMIBE (Voice Mail Interface Board Enhanced) Description The VMIBE can be installed on the VMIB/AAFB connector, and provides system announcement, ACD/UCD announcement, and User Greeting. Figure 3.5.3 VMIBE ITEM RECORD/PLAY Channel 3 channels...
  • Page 48: Aafbe(Auto Attendant Function Board Enhanced)

    IP LDK-20 Installation Manual Board Installation 3.5.4 AAFBE(Auto Attendant Function Board Enhanced) Description The AAFBE can be installed on the VMIB/AAFB connector, and provides system announcement and ACD/UCD announcement. Figure 3.5.4 AAFBE ITEM RECORD/PLAY Channel 3 channels Max record time:...
  • Page 49: Lanu (Lan Interface Unit)

    IP LDK-20 Installation Manual Board Installation 3.5.5 LANU (LAN interface Unit) Description LANU should be installed on the LANU connector, and provides 1 LAN port of 10Base-T networking. RJ45 Modular Jack, MJ1, is used to interface with the Wide Area Network (WAN) or PC, and has 2 LEDs that indicate the operational state of the LAN port.
  • Page 50: Modu (Modem Function Unit)

    IP LDK-20 Installation Manual Board Installation 3.5.6 MODU (MODEM function Unit) Description MODU should be installed on the MODU connectors, and provides an analog modem connection. It supports Bell, ITU-T, V.34, V.32BIS, V.90 Protocol at 300bps, up to 33Kbps speed rate, and automatic rate negotiation.
  • Page 51: Section 4. Expansion Module Installation

    IP LDK-20 Installation Manual Board Installation SECTION 4. EXPANSION MODULE INSTALLATION IPLDK-20 provides three kinds of expansion modules, VOIM, SLIM and DTIM. CONNECTOR MODULE PORT DESCRIPTION CABLE REMARK TYPE VOIM 1 port RJ45 Voice Over Internet Protocol interface 4 wire...
  • Page 52: Opening And Closing The

    IP LDK-20 Installation Manual Board Installation 4.2 Opening and closing the front cover 4.2.1 Opening the front cover 1. Turn the screw counter-clockwise to loosen as shown in Figure 4.2.1. 2. Lift the front cover in the direction of the arrow as shown:...
  • Page 53: Closing The

    2. Then put the front cover down on a module in the direction of the arrow, as shown. 3. Turn the screws clockwise to tighten, as in the Figure. Figure 4.2.2 Closing the front cover • NOTE For safety reasons, close the front cover and tighten the screws prior to operating the IP LDK-20 System.
  • Page 54: Mounting Expansion Module

    IP LDK-20 Installation Manual Board Installation 4.3 Mounting Expansion Module 4.3.1 Connecting Expansion Module to KSU 1. Insert the expansion module into the slot of basic KSU as show in Figure 4.3.1. 2. Turn the screws clockwise to tighten, as in the Figure.
  • Page 55: Wall Mounting

    IP LDK-20 Installation Manual Board Installation 4.3.2 Wall mounting The KSU with an expansion module is mounted on the wall in the same way with basic KSU and an expansion module itself is not mounted on the wall as shown in Figure 4.3.2.
  • Page 56: External Backup Batteries Connection

    Backup batteries for the basic KSU are used in parallel with an expansion module. The IP LDK-20 MBUB will provide charging current to the batteries during normal AC power operation at a maximum of about 100mA. During battery operation, the battery operation of MBUB and an Expansion Module will be stopped if the AC power re-applied or the battery voltage is too low to maintain full-system operation.
  • Page 57: Voim (Voice Over Internet Protocol Interface Module) Installation

    IP LDK-20 Installation Manual Board Installation 4.5 VOIM (Voice over Internet Protocol Interface Module) Installation Description The VOIM can be installed on the basic KSU and provides the Ethernet interface for S/W applications and VoIP features with optional VoIP daughter board.
  • Page 58: Various Switches And Connectors Functions

    IP LDK-20 Installation Manual Board Installation Figure 4.5.2 VOIB The VOIB is installed in the VOIM and provides various kinds of connectors and RJ45 modular jack for the connection of peripheral boards and miscellaneous functions (refer to the following Table).
  • Page 59: Pin Assignment

    IP LDK-20 Installation Manual Board Installation LED indications Functions Remark DSP HINT interrupt LED (ON: Active, OFF: Idle) Periodic toggle – ON: 1 sec., OFF: 1 sec. Channel8 Seize indication LED (ON: Busy, OFF: Idle) Channel7 Seize indication LED (ON: Busy, OFF: Idle)
  • Page 60: Voiu(Voice Over Internet Protocol Interface Unit)

    IP LDK-20 Installation Manual Board Installation 4.5.2 VOIU(Voice over Internet Protocol Interface Unit) Description The VOIU can be installed on the VOIB through CN2 and CN3 and provides the Ethernet interface for S/W applications and 4 VoIP channels. Figure 4.5.2.1 VOIU Installation...
  • Page 61: Slim(Slt Interface Module) Installation

    IP LDK-20 Installation Manual Board Installation 4.6 SLIM(SLT Interface Module) Installation Description The SLIM provides the eight (8) ports of SLT interface circuits and two DTMF receivers. The connection between the SLIM and Single Line Telephone is performed through RJ45 Modular Jacks, MJ1.
  • Page 62: Dtim(Digital Terminal Interface Module)

    IP LDK-20 Installation Manual Board Installation 4.7 DTIM(Digital Terminal Interface Module) Description The DTIM provides 8 ports of Digital terminal interface and provides 2-wire connection to Digital Keysets. It has module connector, MJ1, which is used to connect Digital Keyset lines to the DTIM.
  • Page 63: Section 5. Terminal Connection

    IPLDK-20 Installation Manual Terminal Connection SECTION 5. TERMINAL CONNECTION 5.1 Terminal Models Various types of digital terminals are used with IP LDK-20 MBUB/DTIB4/DTIB8/DTIM as listed and shown below: MODEL DESCRIPTION LDP-7004N 8 Flexible Button Normal LDP-7004D 4 Flexible Button Display...
  • Page 64: Terminal Cabling Distance

    IPLDK-20 Installation Manual Terminal Connection 5.2 Terminal Cabling Distance Figure 5.2 Terminal Cabling Distance...
  • Page 65: Keyset Connection

    IPLDK-20 Installation Manual Terminal Connection 5.3 Keyset Connection 5.3.1 Digital Keyset The following illustrates how to connect the Digital Keyset to your system: Figure 5.3.1 Digital Keyset Connection 5.3.1.1 Pin Assignment CONNECTOR TYPE PIN NUMBER SIGNAL NAME RJ11 RESERVED RING RESERVED 5.3.2 SLT The following illustrates how to connect the SLT to your system:...
  • Page 66: Connecting Additional Terminals

    IPLDK-20 Installation Manual Terminal Connection 5.4 Connecting Additional Terminals MBUB provides connections for 1 external music source, 1 external page port, 2 relay contacts, and an alarm/door- bell input monitor through the PJ1 audio jack and a MJ4 RJ45 Modular Jack. Figure 5.4.1 Additional Terminal Connection 5.4.1 External Music Source wiring MBUB accommodates 1 port of external music source through a PJ1 (RED) audio Jack.
  • Page 67: Section 6. Starting The Ipldk-20 System

    OFF, to protect the various features addressed by Admin Programming after system power-up and initialization. 6.2 Basic Preprogramming The IP LDK-20 System can be programmed to meet an individual customer's need. There are two ways to perform ADMIN Programming: - PC ADMIN : Refer to the PC ADMIN Programming Manual.
  • Page 68 6.2.1.1 Button explanation There are many kinds of DKTUs capable of connecting to the IP LDK-20 system. Figure 6.2.1 shows a model of the LDP-7024D and illustrates each button. Detailed DKTU information for this and other keysets is described in the DKTU User Guide and Installation Manual.
  • Page 69: Entering Programming Mode

    IPLDK-20 Installation Manual Starting the IP LDK-20 System 6.2.2 Entering programming mode To enter Programming Mode, perform the following Steps: Lift the handset Press the [MON] button on the ADMIN station, and hear ICM dial tone. 1. Press the [TRANS/PGM] button and dial •# .
  • Page 70: Pre-Programming

    IPLDK-20 Installation Manual Starting the IP LDK-20 System 6.2.3 Pre-programming Location PGM-Nation Code & Site Name (PGM100) • NOTE : The 4th pole of the DIP switch (SW 3) on the MPB must be turned ON. Procedure Nation Code To program the Nation code, perform the following Steps: 1.
  • Page 71 IPLDK-20 Installation Manual Starting the IP LDK-20 System International Calling Codes NATION CODE NATION CODE NATION CODE America Argentina Australia Bahrain Bangladesh Belgium Bolivia Brazil Brunei Burma Cameroon Chile China (Taiwan) Colombia Costa Rica Cyprus Czech Denmark Ecuador Egypt El Salvador...
  • Page 72 IPLDK-20 Installation Manual Starting the IP LDK-20 System 6.2.3.1 Numbering Plan Type (PGM 104) PROCEDURE 1. Press [Trans/PGM] + 104, then enter the Number Plan Type (Refer to following Table, press 1 digit). 2. Press [HOLD/SAVE] to accept change. Number Plan Type...
  • Page 73 IPLDK-20 Installation Manual Starting the IP LDK-20 System 6.2.3.2 FLEXIBLE NUMBERING PLAN (PGM 105) PROCEDURE To set your flexible numbering plan, perform the following Steps: 1. Press [Trans/PGM] + 105, then enter the station range (dial start and end station numbers).
  • Page 74 IPLDK-20 Installation Manual Starting the IP LDK-20 System 6.2.3.3 Flexible Numbering Plan (PGM 106-107) PROCEDURE Plan A (106) 1. Press [Trans/PGM] + 106, then press the Flexible Button you wish to program (1-24). 2. Enter the code (refer to following Table).
  • Page 75 IPLDK-20 Installation Manual Starting the IP LDK-20 System Flex Numbering Plan B (PGM 107) DEFAULT VALUE FLEX ITEM (AT NUMBERING PLAN TYPE 1) Alarm Reset Group Call Pick-Up UCD Group DND Night Answer Call Park Location Range 601 – 608 Direct Call Pick-Up 801 –...
  • Page 76 IPLDK-20 Installation Manual Starting the IP LDK-20 System 6.2.3.4 IP setting for System (PGM 108) PROCEDURE IP Name (Use the # to skip) 1. Press [Trans/PGM] + 108, then press [FLEX1]. 2. Enter the code (max. 16 characters). 3. Press [HOLD/SAVE] to accept change.
  • Page 77: Section 7. Troubleshooting

    IP LDK-20 Installation Manual Troubleshooting SECTION 7. TROUBLESHOOTING PROBLEM CAUSE / SYMPTOM SOLUTION Power short circuit in Exchange the malfunctioning board for one in good working some board(s) condition. System power failure Dust each board. LD6 LED light on the MBUB Check the PSU fuse.

Table of Contents