3. AC Smart Menu
In the ventilator, you can set the following control command.
Item
Operation
Mode
Fan level
Lock
User mode
3-36
AC Smart
You can set the operation and stopping of the ventilator.
- Operation: You can operate the ventilator.
- Stop: You can stop the operation of the ventilator.
You can designate the operating mode of the ventilator.
- Heat: Both inlet/outlet go through heat exchange device for ventilation. Use
this mode during summer and winter when the difference between the
indoor and outdoor is significant in terms of temperature and humidity.
- Normal: The exhaust air is ventilated without going through the heat
exchanger. Use this mode during spring and fall when the difference
between the indoor and outdoor is not too significant in terms of
temperature and humidity.
- Auto: This measures the indoor temperature and outdoor temperature and
automatically controls inlet and outlet. With this, the balance of the
indoor air is maintained to maintain the optimal condition.
This sets the fan speed of the ventilator. You can adjust the level by considering
the indoor level of contamination.
- Low: This sets the fan level to low.
- High: This sets the fan level to high.
- Super: This sets the fan level to maximum speed.
- Auto: This is set to maintain the optimal condition by measuring the indoor
level of contamination automatically.
You can set the lock function so that the user cannot operate the ventilator
individually.
- All lock: This is set so that the ventilator cannot be operated.
- All unlock: This is set so that the ventilator can be operated.
You can designate the additional operating method of the ventilator.
- Enable plasma: This enables the plasma function. Current this cannot be
designated.
- Disable plasma: This disables the plasma function. Currently this cannot be
designated.
- Enable heater: You can enable the heater function to provide heated air during
the winter when the outdoor air is cold.
- Disable heater: This disable the heater function.
- Enable power save: Ventilator operates in the most efficient condition to save
the power consumption.
- Disable power save: This disables the power save function.
- Enable quick operation: This enables the unit to operate in maximum
- Disable quick operation: If the quick operation mode is in operation, this stops
Description
performance to prevent the expansion of
contaminated indoor air or humidity to other space.
It is recommended to use this when the indoor
contamination is severe.
the operation.