Toro 25430A Operator's Manual page 40

Traction unit
Hide thumbs Also See for 25430A:
Table of Contents

Advertisement

Figure 45
1. Latch
2. Air-cleaner cover
Checking the Restricted Air-cleaner
Light
Service Interval: Before each use or daily
1. Start the engine; refer to Starting the Engine (page 25).
2. Check the restricted air-cleaner light on the instrument
cluster (Figure 46).
Figure 46
1. Restricted air-cleaner light
3. Replace the air-cleaner element(s) as follows:
A. Replace the primary air-cleaner element; refer to
Replacing the Primary Element (page 41).
B. Repeat steps 1 and 2.
C. If the restricted air-cleaner light still comes on,
replace the secondary air-cleaner element; refer to
Replacing the Secondary Element (page 41).
3. Dust valve
2. Instrument cluster
Removing the Air-cleaner Cover
1. Remove the left side panel; refer to Removing the Side
Panels (page 35).
2. Pull the latch for the air-cleaner cover outward (Figure
45).
3. Rotate the cleaner cover counterclockwise so that the
dust cap is at the 7 o'clock position (Figure 47).
1. Latch
2. Air-cleaner cover
4. Pull the air-cleaner cover away from the cleaner housing
to remove the cover.
5. Clean the inside of the cover with a clean damp cloth.
40
Figure 47
3. Dust cap