Danger of injury.
Miele cannot be held liable for unau-
thorised installation, maintenance
and repair work as this can be dan-
gerous to users.
Miele cannot be held liable for dam-
age or injury caused by incorrect in-
stallation, maintenance or repair
work, or by an inadequate or faulty
earthing system (e.g. electric shock).
This hob must be connected to the
mains electrical supply by a suitably
qualified and competent person, in
accordance with current local and
national safety regulations (BS 7671
in the UK).
After installation ensure that all elec-
trical components are shielded and
cannot be accessed by users.

Electrical connection

Connection
AC 230 V, 50 Hz
The connection data is quoted on the
dataplate. It must match the household
supply.
Please see wiring diagram for connec-
tion. (N.B. This appliance is supplied
single phase only in the UK / AUS / NZ).
Residual current device
For extra safety, it is advisable to pro-
tect the appliance with a suitable resid-
ual current device (RCD) with a trip
range of 30 mA.
Separators
The appliance must be able to be dis-
connected from the mains on all poles
by disconnecting devices. When
switched off there must be an all-pole
contact gap of at least 3 mm in the isol-
ator switch. Disconnecting devices in-
clude overcurrent protection and circuit
breakers.
73