Preface The PRIMERGY RX200 S3 is an Intel-based server for mid-tier applications in server farms. The server is well suited for front end services as well as for use as an e-mail server, Internet server, or general applications server. Overview of the documentation...
Page 6
Overview of the documentation Preface Information/activity Manual Performance features and technical data of Operating Manual the server Installation and activation, including: – External connections to the server – Operation – Configuration of the server – Installation of the rack mounting kit Troubleshooting Installation/removal of all hot-plug compo- nents:...
Notational conventions Information/activity Manual BIOS settings BIOS Setup Detailed security information Security Manual Table 1: Overview of the RX200 S2 documentation (part 2 of 2) Notational conventions The following notational conventions are used in this manual: indicate commands, menu items or software programs. Italics “Quotation marks”...
Procedure CAUTION! The actions described in this manual should only be performed by engineers, service personnel or technical specialists. Ê First of all please familiarize yourself with the safety instructions in the chapter “Safety Instructions” on page 11f. Ê Make sure that all required manuals (see Service-DVD) are available, printing out the PDF files if necessary.
Safety Instructions The following safety instructions can also be found in the manual entitled “Safety”. This device complies with the relevant safety regulations for data processing equipment, including electronic office machines for use in an office environment. If you have any questions as to whether you can set up the device in your particular environment, please contact your sales outlet or our customer service centre.
Page 12
Safety Instructions Installation and operation CAUTION! ● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.
Page 13
Safety Instructions CAUTION! ● Be careful to ensure that no objects (e.g. jewelry, paper clips etc.) or liquids get inside the device (electric shock, short circuit). In emergencies (e.g. damaged casing, elements, or cables, penetration of liquids or foreign bodies), switch off the device immedi- ately, remove the power connector from the grounded power outlet, and contact your customer service centre.
Page 14
Safety Instructions Batteries CAUTION! ● Incorrect replacement of batteries may lead to risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the Technical Manual for the system board). Do not throw batteries into the trash can.
Page 15
Safety Instructions To protect the CD-ROM/DVD drive and prevent mechanical damage, as well as premature wearing of the CDs, you should observe the following advice: – Only insert the CDs in the drive when needed and remove them after use. –...
Page 16
Safety Instructions CAUTION! ● Always hold components with ESDs at the points marked green (touch points). Do not touch any exposed pins or conductors on a component. ● Place all components on a static-free base. ● You will find a detailed description of handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).
Replacing components CAUTION! When handling systems and boards, make sure you observe the safety information in the chapter "Safety Instructions" on page 11ff. Preparation To replace components which are not hot-pluggable, proceed as follows: Ê Exit all applications and shut down the server correctly. Ê...
Page 18
Pulling out / removing the server Replacing components CAUTION! The server has no cable management in the rack! Therefore you must unplug all cables connected to server before you remove it. CAUTION! At least two people are needed to remove the server from the rack.
Replacing components Opening/closing the server Opening/closing the server Figure 4: Removing the housing cover Ê To take off the housing cover, press the button (1). Ê Slide the cover about 1 cm backward (2) and lift it off. To close the server, follow the instructions above in reverse. Service Supplement RX200 S3...
Replacing the control panel kit Replacing components Replacing the control panel kit Requirements – The server has been switched off – The power cables have been uplugged – The housing cover has been removed Figure 5: Removing the control panel Ê...
ID prom must be reprogrammed with the ChassisIDProm tool after the new control panel board has been installed. The tool can be found on the ServerSupport CD or downloaded from the Fujitsu Siemens Computers service and support area on the Internet (http://extranet.fujitsu-siemens.com/service/information/intelservers/tools). Service Supplement...
Replacing the fan backplane Replacing components Replacing the fan backplane Requirements – The server has been switched off – The power cables have been uplugged – The housing cover has been removed – The hot-plug fans have been removed (see Operating Manual) Ê...
Replacing components Replacing the SAS backplane for 3.5-inch drives Replacing the SAS backplane for 3.5-inch drives Requirements – The server has been switched off – The power cables have been uplugged – The housing cover has been removed Ê Pull both hard disk modules out a little. Ê...
Replacing the SAS backplane for 2.5-inch drives Replacing components Replacing the SAS backplane for 2.5-inch drives Requirements – The server has been switched off – The power cables have been uplugged – The housing cover has been removed Ê Pull all hard disk modules out a little. Ê...
Replacing components Replacing the power-sharing board Replacing the power-sharing board (power backplane) The power-sharing board comprises a power backplane, power supply fans and a housing. In the case of a defect, you must replace the complete unit. Requirements – The server has been switched off –...
Page 26
Replacing the power-sharing board Replacing components 2. Only loosen the screw marked (2) in figure on page 25, and pull the housing a little in the direction of the back of the server (see number (3)). 3. Remove the power-sharing board. To install the power-sharing board follow the above steps in reverse.
Replacing components Replacing the system board 4.10 Replacing the system board Requirements – The server has been switched off – The power cables have been uplugged – The housing cover has been removed Removing the system board Ê Remove the memory modules as described in the Options Guide. Ê...
Page 28
Replacing the system board Replacing components Installing the system board Ê Insert the system board at a slight angle and push the connectors into the external connection panel. You will have to overcome a slight spring resistance. Ê Carefully lower the system board into the housing. If necessary, adjust the position of the system board by turning it slightly.
Settings IMPORTANT! Make sure you observe the safety notes on page 11ff. Control panel board (LED board) Part number: A3C40073778 Figure 12: Control panel board Connection Universal Serial Bus (USB) Universal Serial Bus (USB) Service Supplement RX200 S3...
Backplanes for SAS drives Settings Backplanes for SAS drives 5.2.1 SAS backplane for 3.5-inch drives Part number: SNP: A3C40073766 Bild 13: Connector assignment of the SAS backplane Connection LED cable Auxiliary power supply for the SAS backplane SAS data cable Service Supplement RX200 S3...
Settings Backplanes for SAS drives 5.2.2 SAS backplane for 2.5-inch drives Part number: SNP: A3C40073772 Figure 14: Connector assignment of the SAS backplane for 2.5-inch drives Connection SAS data cable Auxiliary power supply for the SAS backplane LED cable Service Supplement RX200 S3...
Fan backplane Settings Fan backplane Part number: SNP: A3C40073773 Figure 15: Connector assignment of the fan backplane Connection IDE cable for CD-ROM/DVD drive System fan 9/10 System fan 7/8 System fan 5/6 System fan 3/4 System fan 1/2 Auxiliary power supply for the fan backplane Service Supplement RX200 S3...
Settings Power-sharing board Power-sharing board Part number: SNP:A3C40073782 Figure 16: Connectors of the power-sharing board (power backplane) Connection Power supply unit fan 1 Power supply unit fan 2 Power supply unit fan 3 Error LED Service Supplement RX200 S3...
Cabling Cable overview Part number Description From (soldered to Power- Main Power cable Power- System board D2300 sharing Board) sharing Board (soldered to Power- PBL-I²C Bus cable Power- System board D2300 sharing Board) sharing Board (soldered to Power- AUX voltage cable Power- Fan backplane sharing Board)
Abbreviations Alternating Current ANSI American National Standard Institute ASR&R Automatic Server Reconfiguration and Restart BIOS Basic Input/Output System Baseboard Management Controller Cache Coherency Compact Disk CD-ROM Compact Disk Read Only Memory Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor Communication Central Processing Unit Direct Current Service Supplement...
Page 38
Abbreviations DIMM Dual Inline Memory Module Dual Inline Package Direct Memory Access Desktop Management Interface Errror Checking and Correcting Extended Capabilities Port EEPROM Electrically Erasable Programmable Read-Only Memory Emergency Management Port Enhanced Parallel Port ElectroStatic Discharge (elektrostatische Entladung) Front Panel Controller Field Replaceable Unit Front Side Bus Global Array Manager...
Abbreviations Graphical User Interface Hard Disk Drive Hot-Swap Controller I²C Inter-Integrated Circuit Input/Output Intelligent Chassis Management Identification Intergrated Drive Electronics Interrupt Request Line Local Area Network Logical Block Address Liquid Crystal Display Logical Unit Number Low-Voltage Differential SCSI Service Supplement RX200 S3...
Page 40
Abbreviations Multi-Mode Fibre Manually Retention Latch Non Maskable Interrupt NVRAM Non Volatile Random Access Memory Operating System Peripheral Component Interconnect Prefailure Detection and Analysing POST Power On Self Test RAID Redundant Arrays of Independent Disks Random Access Memory Read-Only Memory Remote Service Board Real Time Clock RTDS...
Abbreviations SAF-TE SCSI Accessed Fault-Tolerant Enclosure Single Bit Error Single Connector Attachment SCSI Small Computer System Interface Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory System Event Log System Management Interrupt System Setup Utility SVGA Super Video Graphics Adapter Universal Serial Bus Video Graphics Adapter Zero Channel RAID...
Index on handling CDs batteries on the laser cable overview power backplane. See power-sharing cabling layout board chassis ID/temperature sensor power-sharing board replace connectors control panel board part number connectors replace part number control panel kit replace replace chassis ID/temperature sensor electrostatic sensitive devices control panel kit...
Page 45
Comments Fujitsu Siemens Computers GmbH User Documentation Suggestions 33094 Paderborn Germany Corrections Fax: (++49) 700 / 372 00001 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY RX200 S3 Server Service Supplement RX200 S3...
Page 47
Comments Fujitsu Siemens Computers GmbH User Documentation Suggestions 33094 Paderborn Germany Corrections Fax: (++49) 700 / 372 00001 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on PRIMERGY RX200 S3 Server Service Supplement RX200 S3...
Page 49
Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.