2 PRODUCT DESCRIPTION
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
Contact outputs (up to 64)
Control pushbuttons
CyberSentry™ security
Digital counters (8)
Digital elements (48)
Direct inputs and outputs (32)
Disconnect switches
DNP 3.0 or IEC 60870-5-104 protocol
Ethernet Global Data protocol (optional)
a) OVERVIEW
The B30 is available as a 19-inch rack horizontal mount or reduced-size (¾) vertical unit and consists of the following mod-
ules: power supply, CPU, CT/VT, contact input and output, transducer input and output, and inter-relay communications.
Each of these modules can be supplied in a number of configurations specified at the time of ordering. The information
required to completely specify the relay is provided in the following tables (see chapter 3 for full details of relay modules).
Order codes are subject to change without notice. See the GE Multilin ordering page at
http://www.gedigitalenergy.com/multilin/order.htm
NOTE
The order code structure is dependent on the mounting option (horizontal or vertical) and the type of CT/VT modules
(enhanced diagnostic CT/VT modules or HardFiber
following sub-sections.
b) ORDER CODES WITH ENHANCED CT/VT MODULES
The order codes for the horizontal mount units are shown below.
Table 2–3: B30 ORDER CODES FOR HORIZONTAL UNITS
B30
-
*
**
- *
*
* - F
BASE UNIT
B30
|
|
|
|
|
CPU
T
|
|
|
|
U
|
|
|
|
V
|
|
|
|
SOFTWARE
00
|
|
|
01
|
|
|
03
|
|
|
04
|
|
|
A0
|
|
|
A1
|
|
|
A3
|
|
|
A4
|
|
|
B0
|
|
|
B1
|
|
|
B3
|
|
|
B4
|
|
|
D0
|
|
|
D1
|
|
|
D3
|
|
|
D4
|
|
|
GE Multilin
FUNCTION
IEC 61850 communications (optional)
Metering: current, voltage, frequency
Modbus communications
Modbus user map
Non-volatile latches
Non-volatile selector switch
Oscillography
Selector switch
Setting groups (6)
for the latest options.
TM
process bus modules). The order code options are described in the
**
- H
**
- L
**
- N
**
- S
**
- U
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B30 Bus Differential System
FUNCTION
Time synchronization over SNTP
Transducer inputs and outputs
User-definable displays
User-programmable fault reports
User-programmable LEDs
User-programmable pushbuttons
User-programmable self-tests
Virtual inputs (64)
Virtual outputs (96)
**
- W/X
**
Full Size Horizontal Mount
|
|
Base Unit
|
|
RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
|
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
|
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
|
|
No software options
|
|
Ethernet Global Data (EGD) protocol
|
|
IEC 61850 protocol
|
|
IEC 61850 and Ethernet Global Data (EGD) protocols
|
|
CyberSentry Lvl 1
|
|
CyberSentry Lvl 1 and Ethernet Global Data
|
|
CyberSentry Lvl 1 and IEC 61850
|
|
CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
|
|
IEEE 1588
|
|
IEEE 1588 and Ethernet Global Data
|
|
IEEE 1588 and IEC 61850
|
|
IEEE 1588, Ethernet Global Data, and IEC 61850
|
|
IEEE 1588 and CyberSentry Lvl 1
|
|
IEEE 1588, CyberSentry Lvl 1, and Ethernet Global Data
|
|
IEEE 1588, CyberSentry Lvl 1, and IEC 61850
|
|
IEEE 1588, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
2.1 INTRODUCTION
2

2.1.2 ORDERING

2-3

Advertisement

Table of Contents
loading

Table of Contents