Town: Abingdon
Serial number: 12345678
Machine type: PT 8337
Load size: 13 kg
+ Button: Activated
Programme start: 11:30
Programme finished: 12:05
Total operating time: 0 h 35 min
Electrical energy: 12.5 kWh
Gas energy: 0 kWh
Steam energy: 0 kWh
Programme change: 2
(after making your selection and
pressing the rotary dial only the last 3 stops and starts will
be displayed.)
Programme fault: None
Area 1: Drying
Block1: Pre-drying
Process type: Residual moisture
Value: 15 %
Actual residual moisture: 15 %
Duration: 6 min
Max. exhaust temperature: 72 °C
Max. air intake temperature: 122 °C
Area1: Drying
Block2: Drying
Process type: Residual moisture
Value: 0 %
Actual residual moisture: 0 %
Duration: 6 min
Max. exhaust temperature: 78 °C
Max. air intake temperature: 138 °C
Area2: Cooling down
Block: Cooling down
Process type: Cooling down
Value: 50 %
Actual temperature: 50 °C
Duration: 3 min
Max. exhaust temperature: 52 °C
Max. air intake temperature: 95 °C
Residual moisture: -3 %
Delete data
Operating data module
Programme data
Delete data
[
After selecting Delete data the following message will
appear in the display:
Operating data module~ Delete data
Module: 21.02.2009
Total data: 12.07.2009
[
(only the last 3 faults are saved.)
The module menu option can be used to delete the
total data and programme data from the operating
data memory.
The total data option can only be used to delete the
total data from the operating data. The programme
data option can only be used to delete programme
data from the operating data.
After making your selection and pressing the rotary
dial you will be prompted to enter your password.
Password: _ _ _ _
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789
After keying in your password or inserting your
supervisor level key card in the reader the following
security prompt will appear in the display:
Delete operating data?
After pressing the S button the data will be deleted!

Peak load cut-out

If the peak-load cut out function is activated the
heating will switch itself off and any programme
running will be stopped. The following message will
appear in the display:
1
Cottons extra dry
Prog. stopped. Peak load cut-out.
Programme will continue.
Once the peak load has finished, the programme will
continue automatically as before.
If the door is opened during the peak load cut-out the
programme will have to be started again.
e
A
e
A
Optional modules
K
ü
A
S
A
S
f